Feasibility of dual-energy CBCT material decomposition in the human torso with 2D anti-scatter grids and grid-based scatter sampling.
Article in Medical physics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 7 citations in OpenAlex.
- Improving deep learning organ segmentation accuracy in cone-beam CT-guided radiotherapy using a robust scatter suppression method.Physics and imaging in radiation oncology · 2026Article
- Impact of dose allocation between high- and low-kV scans on virtual monoenergetic image quality in developmental dual-energy cone-beam CT for image-guided radiotherapy.Journal of applied clinical medical physics · 2026Article
- Experimental characterization and mitigation of scatter induced spectral contamination in photon counting CBCT for radiotherapy.Medical physics · 2026Article
- A Hybrid Approach Combining Dual-Energy and Inpainting Methods for Metal Artifact Reduction in Dentomaxillofacial CBCT: A Proof-of-Concept Phantom Study.Annals of biomedical engineering · 2025Article
- Fast, automated optimization of virtual monoenergetic images with the dual-energy image synthesizer for cone-beam CT.Journal of applied clinical medical physics · 2025Article
- Investigation of 2D anti-scatter grid implementation in a gantry-mounted cone beam computed tomography system for proton therapy.Physics and imaging in radiation oncology · 2025Article
- MISD-IR: material-image subspace decomposition-based iterative reconstruction with spectrum estimation for dual-energy computed tomography.Quantitative imaging in medicine and surgery · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
1 author at 1 institution in 1 country.
Funding
Abstract
backgroundDual-energy (DE) imaging techniques in cone-beam computed tomography (CBCT) have potential clinical applications, including material quantification and improved tissue visualization. However, the performance of DE CBCT is limited by the effects of scattered radiation, which restricts its use to small object imaging. PURPOSE: This study investigates the feasibility of DE CBCT material decomposition by reducing scatter with a 2D anti-scatter grid and a measurement-based scatter correction method. Specifically, the investigation focuses on iodine quantification accuracy and virtual monoenergetic (VME) imaging in phantoms that mimic head, thorax, abdomen, and pelvis anatomies.
methodsA 2D anti-scatter grid prototype was utilized with a residual scatter correction method in a linac-mounted CBCT system to investigate the effects of robust scatter suppression in DE CBCT. Scans were acquired at 90 and 140 kVp using phantoms that mimic head, thorax, and abdomen/pelvis anatomies. Iodine vials with varying concentrations were placed in each phantom, and CBCT images were decomposed into iodine and water basis material images. The effect of a 2D anti-scatter grid with and without residual scatter correction on iodine concentration quantification and contrast visualization in VME images was evaluated. To benchmark iodine concentration quantification accuracy, a similar set of experiments and DE processing were also performed with a conventional multidetector CT scanner.
resultsIn CBCT images, a 2D grid with or without scatter correction can differentiate iodine and water after DE processing in human torso-sized phantom images. However, iodine quantification errors were up to 10 mg/mL in pelvis phantoms when only the 2D grid was used. Adding scatter correction to 2D-grid CBCT reduced iodine quantification errors below 1.5 mg/mL in pelvis phantoms, comparable to iodine quantification errors in multidetector CT. While a noticeable contrast-to-noise ratio improvement was not observed in VME CBCT images, contrast visualization was substantially better in 40 keV VME images in visual comparisons with 90 and 140 kVp CBCT images across all phantom sizes investigated.
conclusionsThis study indicates that accurate DE decomposition is potentially feasible in DE CBCT of the human torso if robust scatter suppression is achieved with 2D anti-scatter grids and residual scatter correction. This approach can potentially enable better contrast visualization and tissue and contrast agent quantification in various CBCT applications.