ArticleMedical physics2024

Feasibility of dual-energy CBCT material decomposition in the human torso with 2D anti-scatter grids and grid-based scatter sampling.

Cem Altunbas

Open access · greenAbstract read
In one paragraph

Article in Medical physics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
0.8field-weighted citation impact, top 33% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author at 1 institution in 1 country.

Cem AltunbasDepartment of Radiation Oncology, University of Colorado School of Medicine, Aurora, Colorado, USA.
University of Colorado Denver · US

Funding

Improving quantitative accuracy and tissue visualization in CBCT guided radiation therapyR01CA245270 · NCI · UNIVERSITY OF COLORADO DENVER · PI ALTUNBAS, CEM · 2020 to 2025
$2.1M
A dedicated two dimensional antiscatter grid for CBCT in radiation therapyR21CA198462 · NCI · UNIVERSITY OF COLORADO DENVER · PI ALTUNBAS, CEM · 2016 to 2017
$372k
NCI NIH HHS R01 CA245270NCI NIH HHS R21 CA198462
6 · The paper itself

Abstract

backgroundDual-energy (DE) imaging techniques in cone-beam computed tomography (CBCT) have potential clinical applications, including material quantification and improved tissue visualization. However, the performance of DE CBCT is limited by the effects of scattered radiation, which restricts its use to small object imaging. PURPOSE: This study investigates the feasibility of DE CBCT material decomposition by reducing scatter with a 2D anti-scatter grid and a measurement-based scatter correction method. Specifically, the investigation focuses on iodine quantification accuracy and virtual monoenergetic (VME) imaging in phantoms that mimic head, thorax, abdomen, and pelvis anatomies.

methodsA 2D anti-scatter grid prototype was utilized with a residual scatter correction method in a linac-mounted CBCT system to investigate the effects of robust scatter suppression in DE CBCT. Scans were acquired at 90 and 140 kVp using phantoms that mimic head, thorax, and abdomen/pelvis anatomies. Iodine vials with varying concentrations were placed in each phantom, and CBCT images were decomposed into iodine and water basis material images. The effect of a 2D anti-scatter grid with and without residual scatter correction on iodine concentration quantification and contrast visualization in VME images was evaluated. To benchmark iodine concentration quantification accuracy, a similar set of experiments and DE processing were also performed with a conventional multidetector CT scanner.

resultsIn CBCT images, a 2D grid with or without scatter correction can differentiate iodine and water after DE processing in human torso-sized phantom images. However, iodine quantification errors were up to 10 mg/mL in pelvis phantoms when only the 2D grid was used. Adding scatter correction to 2D-grid CBCT reduced iodine quantification errors below 1.5 mg/mL in pelvis phantoms, comparable to iodine quantification errors in multidetector CT. While a noticeable contrast-to-noise ratio improvement was not observed in VME CBCT images, contrast visualization was substantially better in 40 keV VME images in visual comparisons with 90 and 140 kVp CBCT images across all phantom sizes investigated.

conclusionsThis study indicates that accurate DE decomposition is potentially feasible in DE CBCT of the human torso if robust scatter suppression is achieved with 2D anti-scatter grids and residual scatter correction. This approach can potentially enable better contrast visualization and tissue and contrast agent quantification in various CBCT applications.

Indexed as

IodineSpiral Cone-Beam Computed TomographyCone-Beam Computed TomographyFeasibility StudiesHumansPelvisPhantoms, ImagingScattering, RadiationWaterIodineWaterdual energy CBCTquantitative CBCTscatter correction

Identifiers

PMID37477550
PMCPMC11009009
OpenAlexW4384925516

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.