Evidence map›Paper›PMID 37476869›Full record

Trial reportTurkish journal of medical sciences2023

A prospective study for an alternative probe site for pulse oximetry measurement in male patients with severe burn trauma: penile shaf.

Yeşim Andıran Şenaylı, Gülsen Keskin, Mine Akın, Atilla Şenaylı, Rabia Ata, Gökhan Demirtaş, Emrah Şenel

Open access · bronzeAbstract readClinical Trial
In one paragraph

Trial report in Turkish journal of medical sciences, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact, top 95% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 0 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Yeşim Andıran ŞenaylıDepartment of Anesthesia and Reanimation, School of Medicine, Bozok University Yozgat Turkey; Department of Pediatric Surgery, School of Medicine, Ankara Yıldırım Beyazıt University Ankara, Turkey.
Gülsen KeskinDepartment of Anesthesia and Reanimation, Ministry of Health Ankara City Hospital Ankara, Turkey.
Mine AkınDepartment of Anesthesia and Reanimation, Ministry of Health Ankara City Hospital Ankara, Turkey.
Atilla ŞenaylıDepartment of Pediatric Surgery, School of Medicine, Bozok University, Yozgat, Turkey.
Rabia AtaDepartment of Pediatric Surgery, Çam ve Sakura City Hospital İstanbul, Turkey.
Gökhan DemirtaşDepartment of Pediatric Urology, Ministry of Health Ankara City Hospital, Ankara, Turkey.
Emrah ŞenelDepartment of Pediatric Surgery, School of Medicine, Bozok University, Yozgat, Turkey.
Ministry of Health · TRBozok Universitesi · TRIstanbul Metropolitan Municipality · TR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAuthors widely use pulse oximetry in clinical monitoring of heart rate (HR) and peripheral oxygen saturation (SpO2) by attachment to the fingers; however, there can be a need for an alternative attachment site, especially for burned patients. We investigate the availability of a pulse oximeter probe attached to the penile shaft as an alternative site in pediatric male patients if all extremities became unavailable for pulse oximetry measurement due to severe burn and/or trauma.

methodsWe designed a prospective comparative study in a training and research hospital. After local ethical committee approval, pediatric male cases eligible for penile and extremity pulse measurements were evaluated during general anesthesia for medical dressing and/or grafting due to severe burns. One probe was attached to the fingers of the unburned extremity, and the other was to the penile shaft. Furthermore, we recorded SpO2and HR values at 5-min intervals; 0th (baseline), 5th, 10th and 15th minutes. We compared HR and SpO2values measured by the finger probe with those measured by the penile probe.

resultsData of 51 patients (median age, 2.9 years (interquartile range, 2.0-5.0 years)) in whom the duration of dressing was at least 15min were analyzed. There was no significant difference either in comparisons of hemodynamic measurements (HR and SpO2 ) obtainedby finger probe and by a penile probe for each measurement time. The Bland-Altman plot analysis reveals agreement for penile and finger probes with a mean bias value between 0.20 and 0.37 on HR and between 0.43 and -0.20 on SpO2. DISCUSSION: This clinical trial demonstrated that pulse oximetry measurement under nonhypoxic conditions we could perform confidently using penile probes in pediatric male patients whose extremities are unavailable for measurement.

Indexed as

BurnsOximetryChildChild, PreschoolFingersHumansMaleOxygenProspective StudiesOxygenburnschildrenPenileprobepulse oximetry

Identifiers

PMID37476869
PMCPMC10388062
OpenAlexW4367154232

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.