Evidence map›Paper›PMID 37476687›Full record

ArticleFrontiers in physiology2023

Cell-scale hemolysis evaluation of intervenient ventricular assist device based on dissipative particle dynamics.

Zhike Xu, Chenghan Chen, Pengfei Hao, Feng He, Xiwen Zhang

Open access · goldAbstract read
In one paragraph

Article in Frontiers in physiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.9field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 8 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. [Progress in the analysis of hemolysis and coagulation models for interventional micro-axial flow blood pumps].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2024
    Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Zhike XuApplied Mechanics Laboratory, Department of Engineering Mechanics, Tsinghua University, Beijing, China.
Chenghan ChenApplied Mechanics Laboratory, Department of Engineering Mechanics, Tsinghua University, Beijing, China.
Pengfei HaoApplied Mechanics Laboratory, Department of Engineering Mechanics, Tsinghua University, Beijing, China.
Feng HeApplied Mechanics Laboratory, Department of Engineering Mechanics, Tsinghua University, Beijing, China.
Xiwen ZhangApplied Mechanics Laboratory, Department of Engineering Mechanics, Tsinghua University, Beijing, China.
Tsinghua University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Most of the existing hemolysis mechanism studies are carried out on the macro flow scale. They assume that the erythrocyte membranes with different loads will suffer the same damage, which obviously has limitations. Thus, exploring the hemolysis mechanism through the macroscopic flow field information is a tough challenge. In order to further understand the non-physiological shear hemolysis phenomenon at the cell scale, this study used the coarse-grained erythrocytes damage model at the mesoscopic scale based on the transport dissipative particle dynamics (tDPD) method. Combined with computational fluid dynamics the hemolysis of scalarized shear stress (

Indexed as

cell-scale hemolysis simulationdissipative particle dynamicserythrocyte damage modelerythrocyte motion formventricular assist devices

Identifiers

PMID37476687
PMCPMC10354560
OpenAlexW4383198814

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.