Evidence map›Paper›PMID 37476053›Full record

ArticleBioengineering & translational medicine2023

Image-based real-time feedback control of magnetic digital microfluidics by artificial intelligence-empowered rapid object detector for automated in vitro diagnostics.

Yuxuan Tang, Fei Duan, Aiwu Zhou, Pojchanun Kanitthamniyom, Shaobo Luo, Xuyang Hu, Xudong Jiang, Shawn Vasoo, Xiaosheng Zhang, Yi Zhang

Open access · goldAbstract read
In one paragraph

Article in Bioengineering & translational medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
1.7field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 22 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 4 institutions in 2 countries.

Yuxuan TangSchool of Mechanical and Aerospace Engineering Nanyang Technological University Singapore Singapore.
Fei DuanSchool of Mechanical and Aerospace Engineering Nanyang Technological University Singapore Singapore.
Aiwu ZhouSingapore Center for 3D Printing, School of Mechanical and Aerospace Engineering Nanyang Technological University Singapore Singapore.
Pojchanun KanitthamniyomSchool of Mechanical and Aerospace Engineering Nanyang Technological University Singapore Singapore.
Shaobo LuoSchool of Microelectronics Southern University of Science and Technology Shenzhen China.
Xuyang HuChina-Singapore International Joint Research Institute Guangzhou China.
Xudong JiangSchool of Electronic and Electrical Engineering Nanyang Technological University Singapore Singapore.
Shawn VasooNational Center for Infectious Disease Tan Tock Seng Hospital Singapore Singapore.
Xiaosheng ZhangSchool of Electronic Science and Engineering University of Electronic Science and Technology of China Chengdu China.
Yi ZhangSchool of Electronic Science and Engineering University of Electronic Science and Technology of China Chengdu China.ORCID https://orcid.org/0000-0002-1239-3441
Nanyang Technological University · SGUniversity of Electronic Science and Technology of China · CNSouthern University of Science and Technology · CNTan Tock Seng Hospital · SG

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In vitro diagnostics (IVD) plays a critical role in healthcare and public health management. Magnetic digital microfluidics (MDM) perform IVD assays by manipulating droplets on an open substrate with magnetic particles. Automated IVD based on MDM could reduce the risk of accidental exposure to contagious pathogens among healthcare workers. However, it remains challenging to create a fully automated IVD platform based on the MDM technology because of a lack of effective feedback control system to ensure the successful execution of various droplet operations required for IVD. In this work, an artificial intelligence (AI)-empowered MDM platform with image-based real-time feedback control is presented. The AI is trained to recognize droplets and magnetic particles, measure their size, and determine their location and relationship in real time; it shows the ability to rectify failed droplet operations based on the feedback information, a function that is unattainable by conventional MDM platforms, thereby ensuring that the entire IVD process is not interrupted due to the failure of liquid handling. We demonstrate fundamental droplet operations, which include droplet transport, particle extraction, droplet merging and droplet mixing, on the MDM platform and show how the AI rectify failed droplet operations by acting upon the feedback information. Protein quantification and antibiotic resistance detection are performed on this AI-empowered MDM platform, and the results obtained agree well with the benchmarks. We envision that this AI-based feedback approach will be widely adopted not only by MDM but also by other types of digital microfluidic platforms to offer precise and error-free droplet operations for a wide range of automated IVD applications.

Indexed as

artificial intelligenceIn vitro diagnosticsmagnetic digital microfluidics

Identifiers

PMID37476053
PMCPMC10354763
OpenAlexW4306759051

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.