Evidence map›Paper›PMID 37474964›Full record

ArticleBMC pulmonary medicine2023

Covered SEMS failed to cure airway fistula closed by an amplatzer device.

Huibin Lu, Yahua Li, Kewei Ren, Zongming Li, Juanfang Liu, Xuhua Duan, Jianzhuang Ren, Xinwei Han

Abstract read
In one paragraph

Article in BMC pulmonary medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Huibin LuDepartment of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, 450052, Zhengzhou, PR China.
Yahua LiDepartment of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, 450052, Zhengzhou, PR China.
Kewei RenDepartment of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, 450052, Zhengzhou, PR China.
Zongming LiDepartment of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, 450052, Zhengzhou, PR China.
Juanfang LiuDepartment of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, 450052, Zhengzhou, PR China.
Xuhua DuanDepartment of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, 450052, Zhengzhou, PR China.
Jianzhuang RenDepartment of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, 450052, Zhengzhou, PR China.
Xinwei HanDepartment of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, 450052, Zhengzhou, PR China. fcchanxw@zzu.edu.cn.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAirway fistula is a rare but threatening complication associated with high rates of morbidity and mortality. We report the experience of Amplatzer device application in airway fistulae that failed to be cured with a covered self-expandable metallic stent (SEMS). MATERIALS AND

methodsPatients who failed occlusion with a covered self-expandable metallic stent and received Amplatzer device placement from Jan 2015 to Jan 2020 were retrospectively enrolled. A total of 14 patients aged 42 to 66 years (55.14 ± 7.87) were enrolled in this study. The primary diseases, types of fistula, types of stents, duration, size of fistula, and follow-up were recorded.

resultsAll 14 patients with airway fistula failed to be occluded with a covered metallic stent and received Amplatzer device placement. Among the 14 patients, 6 had BPF, 3 had TEF and 5 had GBF. The average stent time was 141.93 ± 65.83 days. The sizes of the fistulae ranged from 3 to 6 mm. After Amplatzer device placement, the KPS score improved from 62.14 ± 4.26 to 75.71 ± 5.13 (P < 0.05). No procedure-related complications occurred. During the 1-month, 3-month and 6-month follow-ups, all the Amplatzer devices were partially surrounded with granulation. Only 1 patient with BPF failed with Amplatzer device occlusion due to the recurrence of lung cancer.

conclusionIn conclusion, the application of the Amplatzer device is a safe and effective option in the treatment of airway fistula that failed to be occluded with SEMSs.

Indexed as

FistulaSelf Expandable Metallic StentsHumansRetrospective StudiesStentsTreatment OutcomeAirway fistulaAmplatzer deviceStent

Identifiers

PMID37474964
PMCPMC10357874

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.