Evidence map›Paper›PMID 37474830›Full record

ArticleJournal of artificial organs : the official journal of the Japanese Society for Artificial Organs2024

Ultrasound vector flow imaging during veno-arterial extracorporeal membrane oxygenation in a thoracic aorta model.

Kenichiro Yambe, Takuro Ishii, Billy Y S Yiu, Alfred C H Yu, Tomoyuki Endo, Yoshifumi Saijo

Abstract read
In one paragraph

Article in Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Kenichiro YambeGraduate School of Medicine, Tohoku University, 2-1 Seiryo-Machi, Aoba-Ku, Sendai, Miyagi, 980-8575, Japan.
Takuro IshiiFrontier Research Institute for Interdisciplinary Sciences, Tohoku University, 6-3 Aramaki Aza Aoba, Aoba-Ku, Sendai, Miyagi, 980-8578, Japan. takuro.ishii@tohoku.ac.jp.ORCID http://orcid.org/0000-0002-7411-3919
Billy Y S YiuResearch Institute for Aging, University of Waterloo, 250 Laurelwood Drive, Waterloo, ON, N2J 0E2, Canada.
Alfred C H YuResearch Institute for Aging, University of Waterloo, 250 Laurelwood Drive, Waterloo, ON, N2J 0E2, Canada.
Tomoyuki EndoDivision of Emergency and Disaster Medicine, Tohoku Medical and Pharmaceutical University, 1-15-1 Fukumuro, Miyagino-Ku, Sendai, Miyagi, 983-8536, Japan.
Yoshifumi SaijoGraduate School of Medicine, Tohoku University, 2-1 Seiryo-Machi, Aoba-Ku, Sendai, Miyagi, 980-8575, Japan.

Funding

Japan Society for the Promotion of Science Leading Initiative for Excellent Young Researchers
6 · The paper itself

Abstract

In veno-arterial extracorporeal membrane oxygenation (VA-ECMO) treatment, the mixing zone is a key hemodynamic factor that determines the efficacy of the treatment. This study aimed to evaluate the applicability of a novel ultrasound technique called vector flow imaging (VFI) for visualizing complex flow patterns in an aorta phantom under VA-ECMO settings. VFI experiments were performed to image aortic hemodynamics under VA-ECMO treatment simulated in an anthropomorphic thoracic aorta phantom using a pulsatile pump (cardiac output: 2.7 L/min) and an ECMO pump with two different flow rates, 0.35 L/min and 1.0 L/min. The cardiac cycle of hemodynamics in the ascending aorta, aortic arch, and descending aorta was visualized, and the spatio-temporal dynamics of flow vectors were analyzed. VFI successfully visualized dynamic flow patterns in the aorta phantom. When the flow rate of the ECMO pump increased, ECMO flow was more dominant than cardiac output in the diastole phase, and the speed of cardiac output was suppressed in the systole phase. Vortex flow patterns were also detected in the ascending aorta and the arch under both ECMO flow rate conditions. The VFI technique may provide new insights into aortic hemodynamics and facilitates effective and safe VA-ECMO treatment.

Indexed as

Aorta, ThoracicExtracorporeal Membrane OxygenationBlood Flow VelocityHemodynamicsHumansPhantoms, ImagingUltrasonographyHemodynamicsMixing zoneThoracic aortaUltrasound flow imagingVA-ECMOVector flow imaging

Identifiers

PMID37474830
PMCPMC11345325

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.