Evidence map›Paper›PMID 37470381›Full record

ArticleJournal of biomaterials applications2023

In vitro evaluation of blood plasma coagulation responses to four medical-grade polyurethane polymers.

Lan Nguyen, Li-Chong Xu, Eric Yeager, William J Weiss, Christopher A Siedlecki

Open access · hybridAbstract read
In one paragraph

Article in Journal of biomaterials applications, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.6field-weighted citation impact, top 38% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Review
  3. The effects of submicron-textured surface topography on antibiotic efficacy against biofilms.Journal of biomedical materials research. Part B, Applied biomaterials · 2024
    Article
  4. Article
  5. Biomimetic polymers with phosphorylcholine groups as biomaterials for medical devices.Proceedings of the Japan Academy. Series B, Physical and biological sciences · 2024
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Lan NguyenDepartment of Biochemistry and Molecular Biology, Gettysburg College, Gettysburg, PA, USA.
Li-Chong XuDepartment of Surgery, The Pennsylvania State University, College of Medicine, Hershey, PA, USA.
Eric YeagerDepartment of Surgery, The Pennsylvania State University, College of Medicine, Hershey, PA, USA.
William J WeissDepartment of Surgery, The Pennsylvania State University, College of Medicine, Hershey, PA, USA.
Christopher A SiedleckiDepartment of Surgery, The Pennsylvania State University, College of Medicine, Hershey, PA, USA.ORCID 0000-0003-2163-4099
Pennsylvania State University · USGettysburg College · US

Funding

Final Pre-clinical Studies for a Ventricular Assist Device for InfantsR01HL151736 · NHLBI · PENNSYLVANIA STATE UNIV HERSHEY MED CTR · PI WEISS, WILLIAM J · 2020 to 2023
$3.1M
Combinatorial Approaches to Improved Blood-contacting Polymer BiomaterialsR01HL153231 · NHLBI · PENNSYLVANIA STATE UNIV HERSHEY MED CTR · PI SIEDLECKI, CHRISTOPHER A · 2020 to 2023
$2.6M
NHLBI NIH HHS R01 HL151736NHLBI NIH HHS R01 HL153231
6 · The paper itself

Abstract

Segmented polyurethane (PU) block copolymers are widely used in implantable cardiovascular medical devices due to their good biocompatibility and excellent mechanical properties. More specifically, PU Biospan MS/0.4 was used in ventricular assist devices over the past decades. However, this product is being discontinued and it has become necessary to find an alternative PU biomaterial for application in cardiovascular devices. One important criterion for assessing cardiac biomaterials is blood compatibility. In this study, we characterized the surface properties of four medical-grade PU biomaterials: Biospan MS/0.4, BioSpan S, BioSpan 2F, and CarboSil 20 80A, including surface chemistry, topography, microphase separation structure and wettability, and then measured the blood plasma coagulation responses using bovine and human blood plasma. Results showed that BioSpan 2F contains high amounts of fluorine and has the lowest surface free energy while the other materials have surfaces with silicone present. An in vitro coagulation assay shows that these materials demonstrated improved blood coagulation responses compared to the polystyrene control and there were no significant differences in coagulation time among all PU biomaterials. The chromogenic assay showed all PU materials led to low FXII contact activation, and there were no significant differences in FXII contact activation, consistent with plasma coagulation responses.

Indexed as

PolymersPolyurethanesAnimalsBiocompatible MaterialsBlood CoagulationCattleHumansPlasmaSurface PropertiesBiocompatible Materialspolyetherurethane ureaPolymersPolyurethanesblood coagulationFXII activationPolyurethanesurface characterization

Identifiers

PMID37470381
PMCPMC10408244
OpenAlexW4384784906

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.