Evidence map›Paper›PMID 37469883›Full record

ArticleACS applied polymer materials2023

An Edible Humidity Indicator That Responds to Changes in Humidity Mechanically.

Mengmeng Zhang, Abinaya Arunachalam, Hugo Perrin, Sevgi Polat, Jan Groenewold, Eduardo Mendes, Hüseyin Burak Eral

Open access · hybridAbstract read
In one paragraph

Article in ACS applied polymer materials, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.5field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 14 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 5 institutions in 3 countries.

Mengmeng ZhangProcess & Energy Department, Delft University of Technology, Leeghwaterstraat 39, 2628 CB Delft, The Netherlands.ORCID https://orcid.org/0000-0001-8615-1851
Abinaya ArunachalamProcess & Energy Department, Delft University of Technology, Leeghwaterstraat 39, 2628 CB Delft, The Netherlands.ORCID https://orcid.org/0000-0002-2185-5644
Hugo PerrinProcess & Energy Department, Delft University of Technology, Leeghwaterstraat 39, 2628 CB Delft, The Netherlands.
Sevgi PolatProcess & Energy Department, Delft University of Technology, Leeghwaterstraat 39, 2628 CB Delft, The Netherlands.ORCID https://orcid.org/0000-0002-0934-2125
Jan GroenewoldVan't Hoff Laboratory, Physical Chemistry, University of Utrecht, Padualaan 8, 3584 CH Utrecht, The Netherlands.
Eduardo MendesChemical Engineering, Faculty of Applied Sciences, Delft University of Technology, Van der Maasweg 9, Delft, South Holland 2629 HZ, The Netherlands.ORCID https://orcid.org/0000-0002-7519-0668
Hüseyin Burak EralProcess & Energy Department, Delft University of Technology, Leeghwaterstraat 39, 2628 CB Delft, The Netherlands.ORCID https://orcid.org/0000-0003-3193-452X
Delft University of Technology · NLMarmara University · TRSouth China Normal University · CNUniversity of Groningen · NLUtrecht University · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Elevated humidity levels in medical, food, and pharmaceutical products may reduce the products' shelf life, trigger bacterial growth, and even lead to complete spoilage. In this study, we report a humidity indicator that mechanically bends and rolls itself irreversibly upon exposure to high humidity conditions. The indicator is made of two food-grade polymer films with distinct ratios of a milk protein, casein, and a plasticizer, glycerol, that are physically attached to each other. Based on the thermogravimetric analysis and microstructural characterization, we hypothesize that the bending mechanism is a result of hygroscopic swelling and consequent counter diffusion of water and glycerol. Guided by this mechanism, we demonstrate that the rolling behavior, including response time and final curvature, can be tuned by the geometric dimensions of the indicator. As the proposed indicator is made of food-grade ingredients, it can be placed directly in contact with perishable products to report exposure to undesirable humidity inside the package, without the risk of contaminating the product or causing oral toxicity in case of accidental digestion, features that commercial inedible electronic and chemo-chromatic sensors cannot provide presently.

Identifiers

PMID37469883
PMCPMC10353009
OpenAlexW4379468965

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.