Fully printed and self-compensated bioresorbable electrochemical devices based on galvanic coupling for continuous glucose monitoring.

Jiameng Li, Jiayin Liu, Ziyue Wu, Xue Shang, Ya Li, Wenxing Huo, Xian Huang

Open access · goldAbstract read
In one paragraph

Article in Science advances, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
5.0field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 38 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. A Review on Biodegradable Materials of Sustainable Soft Robotics and Electronics.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
    Review
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
  11. Bioresorbable electrodes in implantable electronic healthcare devices.Frontiers in bioengineering and biotechnology · 2025
    Review
  12. Article
  13. Article
  14. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Jiameng LiDepartment of Biomedical Engineering, Tianjin University, 92 Weijin Road, Tianjin 300072, China.ORCID 0000-0001-9714-0090
Jiayin LiuDepartment of Biomedical Engineering, Tianjin University, 92 Weijin Road, Tianjin 300072, China.ORCID 0000-0002-5419-4088
Ziyue WuDepartment of Biomedical Engineering, Tianjin University, 92 Weijin Road, Tianjin 300072, China.
Xue ShangDepartment of Biomedical Engineering, Tianjin University, 92 Weijin Road, Tianjin 300072, China.ORCID 0009-0001-4895-2604
Ya LiDepartment of Biomedical Engineering, Tianjin University, 92 Weijin Road, Tianjin 300072, China.
Wenxing HuoDepartment of Biomedical Engineering, Tianjin University, 92 Weijin Road, Tianjin 300072, China.ORCID 0000-0002-1832-9328
Xian HuangDepartment of Biomedical Engineering, Tianjin University, 92 Weijin Road, Tianjin 300072, China.ORCID 0000-0002-8788-9185
Tianjin University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Real-time glucose monitoring conventionally involves non-bioresorbable semi-implantable glucose sensors, causing infection and pain during removal. Despite bioresorbable electronics serves as excellent alternatives, the bioresorbable sensor dissolves in aqueous environments with interferential biomolecules. Here, the theories to achieve stable electrode potential and accurate electrochemical detection using bioresorbable materials have been proposed, resulting in a fully printed bioresorbable electrochemical device. The adverse effect caused by material degradation has been overcome by a molybdenum-tungsten reference electrode that offers stable potential through galvanic-coupling and self-compensation modules. In vitro and in vivo glucose monitoring has been conducted for 7 and 5 days, respectively, followed by full degradation within 2 months. The device offers a glucose detection range of 0 to 25 millimolars and a sensitivity of 0.2458 microamperes per millimolar with anti-interference capability and biocompatibility, indicating the possibility of mass manufacturing high-performance bioresorbable electrochemical devices using printing and low-temperature water-sintering techniques. The mechanisms may be implemented developing more comprehensive bioresorbable sensors for chronic diseases.

Indexed as

Blood GlucoseBlood Glucose Self-MonitoringAbsorbable ImplantsElectrochemical TechniquesElectrodesElectronicsBlood Glucose

Identifiers

PMID37467335
PMCPMC10355816
OpenAlexW4384820579

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.