Evidence map›Paper›PMID 37466783›Full record

ArticleInternational journal of computer assisted radiology and surgery2024

Diameters of lingual, facial, and maxillary arteries measured according to an objective protocol on 3D computed tomography angiography images.

Takashi Ohya, Ichiro Sakuma, Wenran Cai, Etsuko Kobayashi, Toshiyuki Koizumi, Kenji Mitsudo

Abstract read
PubMed Publisher
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.5field-weighted citation impact, top 36% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Takashi OhyaDepartment of Oral and Maxillofacial Surgery, Yokohama City University Graduate School of Medicine, Yokohama, Japan. tohya33@yokohama-cu.ac.jp.ORCID http://orcid.org/0000-0002-0094-2722
Ichiro SakumaGraduate School of Engineering, The University of Tokyo, Tokyo, Japan.
Wenran CaiGraduate School of Engineering, The University of Tokyo, Tokyo, Japan.
Etsuko KobayashiGraduate School of Engineering, The University of Tokyo, Tokyo, Japan.
Toshiyuki KoizumiDepartment of Oral and Maxillofacial Surgery, Yokohama City University Graduate School of Medicine, Yokohama, Japan.
Kenji MitsudoDepartment of Oral and Maxillofacial Surgery, Yokohama City University Graduate School of Medicine, Yokohama, Japan.
The University of Tokyo · JPYokohama City University · JP

Funding

Japan Society for the Promotion of Science JP20H04553
6 · The paper itself

Abstract

purposeRetrograde superselective intra-arterial chemoradiotherapy is a radical treatment for advanced oral cancer. The catheter tip is placed into tumor-feeding arteries-the lingual, facial, or maxillary arteries. The diameter of the tumor-feeding arteries newly bifurcated from the external carotid artery is crucial for determining the requirement of a catheter navigation system. This study aimed to measure the diameter and distribution of the tumor-feeding artery according to an objective protocol using 3D computed tomography angiography images reproducibly.

methodsAngiographic data of 20 noncatheterized carotid arteriesof 10 randomly selected patients were analyzed. We followed the external carotid artery to the entrance of each feeding artery to determine the center point where the artery diameter was measured. The diameter of the optimum circle measured at the adopted center point was taken as the diameter of each tumor-feeding artery.

resultsThe diameters (mean ± standard deviation) were 3.5 ± 0.45, 2.9 ± 0.56, and 3.5 ± 0.56 mm for the maxillary, lingual, and facial arteries, respectively. The diameters of the maxillary and facial arteries were similar (p = 0.877), whereas the diameter of the lingual artery was smaller than that of the maxillary and facial arteries (p < 0.001).

conclusionThe findings of this study will be beneficial in determining the need of a new catheter navigation system and diameter of catheters to be used in the clinical practice. From the viewpoint of measurement automation and reproducibility, 3DCTA vessel measurement taken according to the proposed protocol was considered to be effective.

Indexed as

Maxillary ArteryNeoplasmsCarotid ArteriesComputed Tomography AngiographyHumansInfusions, Intra-ArterialReproducibility of Results3D computed tomography angiographyCarotid arteryDiameterIntra-arterial infusionTumor-feeding artery

Identifiers

PMID37466783
OpenAlexW4384663116

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.