Evidence map›Paper›PMID 37466650›Full record

ArticleEuropean journal of nuclear medicine and molecular imaging2023

Walk-through flat panel total-body PET: a patient-centered design for high throughput imaging at lower cost using DOI-capable high-resolution monolithic detectors.

Stefaan Vandenberghe, Florence M Muller, Nadia Withofs, Meysam Dadgar, Jens Maebe, Boris Vervenne, Maya Abi Akl, Song Xue, Kuangyu Shi, Giancarlo Sportelli and 4 more

Open access · hybridAbstract read
In one paragraph

Article in European journal of nuclear medicine and molecular imaging, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 19 papers.

0numbers the graph read from it
0cells of the map it votes in
19citing papers in PubMed
5.5field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

19 citing papers in PubMed, 24 citations in OpenAlex.

  1. Review
  2. Article
  3. Review
  4. Large axial field of view PET/CT - Not just a longer PET gantry.Zeitschrift fur medizinische Physik · 2026
    Review
  5. Article
  6. Article
  7. Article
  8. Review
  9. Review
  10. Article
  11. Total-Body PET System Designs with Axial and Transverse Gaps: A Study of Lesion Quantification and Detectability.Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2025
    Article
  12. Total Body PET/CT: Future Aspects.Seminars in nuclear medicine · 2025
    Review
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors at 4 institutions in 3 countries.

Stefaan VandenbergheMedical Image and Signal Processing, Department of Electronics and Information Systems, Faculty of Engineering and Architecture, Ghent University, Corneel Heymanslaan 10, 9000, Ghent, Belgium. Stefaan.Vandenberghe@ugent.be.ORCID 0000-0002-2377-3968
Florence M MullerMedical Image and Signal Processing, Department of Electronics and Information Systems, Faculty of Engineering and Architecture, Ghent University, Corneel Heymanslaan 10, 9000, Ghent, Belgium.
Nadia WithofsDivision of Nuclear Medicine and Oncological Imaging, Department of Medical Physics, CHU of Liege, Quartier Hôpital, Avenue de Hôpital, 1, 4000, Liège 1, Belgium.
Meysam DadgarMedical Image and Signal Processing, Department of Electronics and Information Systems, Faculty of Engineering and Architecture, Ghent University, Corneel Heymanslaan 10, 9000, Ghent, Belgium.
Jens MaebeMedical Image and Signal Processing, Department of Electronics and Information Systems, Faculty of Engineering and Architecture, Ghent University, Corneel Heymanslaan 10, 9000, Ghent, Belgium.
Boris VervenneMedical Image and Signal Processing, Department of Electronics and Information Systems, Faculty of Engineering and Architecture, Ghent University, Corneel Heymanslaan 10, 9000, Ghent, Belgium.
Maya Abi AklMedical Image and Signal Processing, Department of Electronics and Information Systems, Faculty of Engineering and Architecture, Ghent University, Corneel Heymanslaan 10, 9000, Ghent, Belgium.
Song XueDepartment of Nuclear Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
Kuangyu ShiDivision of Nuclear Medicine and Oncological Imaging, Department of Medical Physics, CHU of Liege, Quartier Hôpital, Avenue de Hôpital, 1, 4000, Liège 1, Belgium.
Giancarlo SportelliDipartimento Di Fisica "E. Fermi", Università Di Pisa, Italy and with the Instituto Nazionale Di Fisica Nucleare, Sezione Di Pisa, 56127, Pisa, Italy.
Nicola BelcariDipartimento Di Fisica "E. Fermi", Università Di Pisa, Italy and with the Instituto Nazionale Di Fisica Nucleare, Sezione Di Pisa, 56127, Pisa, Italy.
Roland HustinxDivision of Nuclear Medicine and Oncological Imaging, Department of Medical Physics, CHU of Liege, Quartier Hôpital, Avenue de Hôpital, 1, 4000, Liège 1, Belgium.
Christian VanhoveMedical Image and Signal Processing, Department of Electronics and Information Systems, Faculty of Engineering and Architecture, Ghent University, Corneel Heymanslaan 10, 9000, Ghent, Belgium.
Joel S KarpPhysics and Instrumentation, Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA.
Ghent University · BECentre Hospitalier Universitaire de Liège · BEUniversity of Bern · CHUniversity of Pennsylvania · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeLong axial field-of-view (LAFOV) systems have a much higher sensitivity than standard axial field-of-view (SAFOV) PET systems for imaging the torso or full body, which allows faster and/or lower dose imaging. Despite its very high sensitivity, current total-body PET (TB-PET) throughput is limited by patient handling (positioning on the bed) and often a shortage of available personnel. This factor, combined with high system costs, makes it hard to justify the implementation of these systems for many academic and nearly all routine nuclear medicine departments. We, therefore, propose a novel, cost-effective, dual flat panel TB-PET system for patients in upright standing positions to avoid the time-consuming positioning on a PET-CT table; the walk-through (WT) TB-PET. We describe a patient-centered, flat panel PET design that offers very efficient patient throughput and uses monolithic detectors (with BGO or LYSO) with depth-of-interaction (DOI) capabilities and high intrinsic spatial resolution. We compare system sensitivity, component costs, and patient throughput of the proposed WT-TB-PET to a SAFOV (= 26 cm) and a LAFOV (= 106 cm) LSO PET systems.

methodsPatient width, height (= top head to start of thighs) and depth (= distance from the bed to front of patient) were derived from 40 randomly selected PET-CT scans to define the design dimensions of the WT-TB-PET. We compare this new PET system to the commercially available Siemens Biograph Vision 600 (SAFOV) and Siemens Quadra (LAFOV) PET-CT in terms of component costs, system sensitivity, and patient throughput. System cost comparison was based on estimating the cost of the two main components in the PET system (Silicon Photomultipliers (SiPMs) and scintillators). Sensitivity values were determined using Gate Monte Carlo simulations. Patient throughput times (including CT and scout scan, patient positioning on bed and transfer) were recorded for 1 day on a Siemens Vision 600 PET. These timing values were then used to estimate the expected patient throughput (assuming an equal patient radiotracer injected activity to patients and considering differences in system sensitivity and time-of-flight information) for WT-TB-PET, SAFOV and LAFOV PET.

resultsThe WT-TB-PET is composed of two flat panels; each is 70 cm wide and 106 cm high, with a 50-cm gap between both panels. These design dimensions were justified by the patient sizes measured from the 40 random PET-CT scans. Each panel consists of 14 × 20 monolithic BGO detector blocks that are 50 × 50 × 16 mm in size and are coupled to a readout with 6 × 6 mm SiPMs arrays. For the WT-TB-PET, the detector surface is reduced by a factor of 1.9 and the scintillator volume by a factor of 2.2 compared to LAFOV PET systems, while demonstrating comparable sensitivity and much better uniform spatial resolution (< 2 mm in all directions over the FOV). The estimated component cost for the WT-TB-PET is 3.3 × lower than that of a 106 cm LAFOV system and only 20% higher than the PET component costs of a SAFOV. The estimated maximum number of patients scanned on a standard 8-h working day increases from 28 (for SAFOV) to 53-60 (for LAFOV in limited/full acceptance) to 87 (for the WT-TB-PET). By scanning faster (more patients), the amount of ordered activity per patient can be reduced drastically: the WT-TB-PET requires 66% less ordered activity per patient than a SAFOV.

conclusionsWe propose a monolithic BGO or LYSO-based WT-TB-PET system with DOI measurements that departs from the classical patient positioning on a table and allows patients to stand upright between two flat panels. The WT-TB-PET system provides a solution to achieve a much lower cost TB-PET approaching the cost of a SAFOV system. High patient throughput is increased by fast patient positioning between two vertical flat panel detectors of high sensitivity. High spatial resolution (< 2 mm) uniform over the FOV is obtained by using DOI-capable monolithic scintillators.

Indexed as

Positron-Emission TomographyPositron Emission Tomography Computed TomographyHumansMonte Carlo MethodPatient-Centered CareBGOCost-lifetime analysisL(Y)SOMonolithic detectorPatient throughputPositron emission tomographyTotal-body PETWalk-through PET

Identifiers

PMID37466650
PMCPMC10547652
OpenAlexW4384664309

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.