Evidence map›Paper›PMID 37466620›Full record

ArticleArquivos brasileiros de cardiologia2023

Transcatheter Valve Replacement in Patients with Aortic Valve Stenosis: An Overview of Systematic Reviews and Meta-Analysis with Different Populations.

Henrique Diegoli, Marcia Regina Dias Alves, Lucas Miyake Okumura, Caroline Kroll, Dayane Silveira, Luiz Henrique Picolo Furlan

Open access · diamondAbstract read
In one paragraph

Article in Arquivos brasileiros de cardiologia, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.4field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 5 institutions in 4 countries.

Henrique DiegoliAcademia VBHC Educação e Consultoria Ltda , São Paulo , SP - Brasil.ORCID 0000-0002-3970-019X
Marcia Regina Dias AlvesEdwards Lifesciences Corporation , São Paulo , SP - Brasil.ORCID 0000-0001-9798-6977
Lucas Miyake OkumuraUniversidade de York , York - Reino Unido.
Caroline KrollUniversidade da Região de Joinville , Joinville , SC - Brasil.
Dayane SilveiraEdwards Lifesciences Corporation , São Paulo , SP - Brasil.ORCID 0000-0002-2059-7217
Luiz Henrique Picolo FurlanUnimed do Paraná , Curitiba , PR - Brasil.
Edwards Lifesciences (United States) · USCentro Universitário Curitiba · BRElabora Consultoria (Brazil) · BRUnited Nations Industrial Development Organization · ATUniversidade da Região de Joinville · BR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundRandomized controlled trials (RCTs) and observational studies have compared the efficacy and safety of transcatheter aortic valve replacement (TAVR) and surgical aortic valve replacement (SAVR) in patients with severe aortic stenosis.

objectivesCompare TAVR and SAVR in patients with different surgical risks, population characteristics, and different transcatheter prosthetic valves.

methodsAn overview of systematic reviews (SRs) was conducted following a structured protocol. Results were grouped by surgical risk, population characteristics, and different valves. RCTs in the SRs were reanalyzed through meta-analyses, and the results were summarized using the GRADE method. The adopted level of statistical significance was 5%.

resultsCompared to SAVR, patients with high surgical risk using TAVR had a lower risk of (odds ratio, 95% confidence interval, absolute risk difference) atrial fibrillation (AF) (0.5, 0.29-0.86, -106/1000) and life-threatening bleeding (0.29, 0.2-0.42, -215/1000). Patients with intermediate surgical risk had a lower risk of AF (0.27, 0.23-0.33, -255/1000), life-threatening bleeding (0.15, 0.12-0.19, -330/1000), and acute renal failure (ARF) (0.4, 0.26-0.62, -21/1000). Patients with low surgical risk had a lower risk of death (0.58, 0.34-0.97, -16/1000), stroke (0.51, 0.28-0.94, -15/1000), AF (0.16, 0.12-0.2, -295/1000), life-threatening bleeding (0.17, 0.05-0.55, -76/1000), and ARF (0.27, 0.13-0.55, -21/1000), and had a higher risk of permanent pacemaker implantation (PPI) (4.22, 1.27-14.02, 141/1000). Newer generation devices had a lower risk of AF than older generations, and patients using balloon-expandable devices did not experience higher risks of PPI.

conclusionsThis paper provides evidence that patients at low, intermediate, and high surgical risks have better outcomes when treated with TAVR compared with SAVR.

Indexed as

Aortic Valve StenosisAtrial FibrillationHeart Valve Prosthesis ImplantationHumansMeta-Analysis as TopicRisk FactorsSystematic Reviews as TopicTreatment Outcome

Identifiers

PMID37466620
PMCPMC10365004
OpenAlexW4383370800

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.