Evidence map›Paper›PMID 37465029›Full record

ArticleMechanics of soft materials2023

A quantitative comparison of devices for in vivo biomechanical characterization of human skin.

Håvar J Junker, Bettina Thumm, Sascha Halvachizadeh, Edoardo Mazza

Abstract read
In one paragraph

Article in Mechanics of soft materials, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Trial
  2. TowardFrontiers in bioengineering and biotechnology · 2026
    Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Correlation analysis between texture features and elasticity of skin hyperspectral images in the near-infrared band.Skin research and technology : official journal of International Society for Bioengineering and the Skin (ISBS) [and] International Society for Digital Imaging of Skin (ISDIS) [and] International Society for Skin Imaging (ISSI) · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Håvar J JunkerPresent address: Institute for Mechanical Systems, Department of Mechanical and Process Engineering, ETH Zurich, Leonhardstrasse 21, Zurich, 8092 Switzerland.ORCID 0000-0001-7503-3614
Bettina ThummPresent address: Institute for Mechanical Systems, Department of Mechanical and Process Engineering, ETH Zurich, Leonhardstrasse 21, Zurich, 8092 Switzerland.
Sascha HalvachizadehDepartment of Trauma, University Hospital Zurich, Rämistrasse 100, Zurich, 8091 Switzerland.
Edoardo MazzaPresent address: Institute for Mechanical Systems, Department of Mechanical and Process Engineering, ETH Zurich, Leonhardstrasse 21, Zurich, 8092 Switzerland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Non-invasive skin characterization devices are emerging as a valuable tool in clinical skin research. In recent years, the range of available experimental techniques and methods used to determine the biomechanical properties of skin has increased considerably. Although a substantial amount of work has been devoted to assessing the working principle of macroscopic skin characterization devices individually, a rationalization and comparison between them is still lacking. This motivated the present study, which aimed to characterize and compare three commonly used working principles: suction, dynamic shear loading, and indentation. A synthetic model system with tunable mechanical properties was used to assess the three devices, and the results rationalized based on corresponding finite element models. In vivo measurements were performed on healthy volunteers to investigate the capability of differentiating the biomechanical properties of skin at different body locations, and to assess the intra- and inter-rater reliability of each device. The present comparative analysis indicates that the analyzed functional principles perceive the stiffness of human skin differently, with relevant implications for the interpretation of the respective measurement results.

Indexed as

MyotonNimbleSkin biomechanicsSkinFibroMeter

Identifiers

PMID37465029
PMCPMC10350442

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.