ArticleJournal of synchrotron radiation2023
ID22 - the high-resolution powder-diffraction beamline at ESRF.
Article in Journal of synchrotron radiation, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 52 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
52 citing papers in PubMed.
- Sublattice-Resolved Magnetoelastic Coupling and Opposing Pressure Responses in the Frustrated Magnetocaloric GdMnAdvanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026Article
- Surface-Stress-Induced Lattice Distortion in Nanolamellar Cementite.Materials (Basel, Switzerland) · 2026Article
- Halochromic modulation of amorphous calcium carbonate crystallization driven by pH-responsive bioinspired pigments.Nature communications · 2026Article
- WebPDF: a browser-based software application for calculating X-ray pair distribution function.Analytical sciences : the international journal of the Japan Society for Analytical Chemistry · 2026Article
- Structural Distortions and Magnetic Ordering inInorganic chemistry · 2026Article
- Reversible hydrogen storage in reactive hydride composites under 400 K.Nature communications · 2026Article
- Elucidation of the Antiferroelectricity Mechanism in CsBi(MoOACS materials Au · 2026Article
- Article
- Structure of HEPES-Reduced δ‑MnOChemistry of materials : a publication of the American Chemical Society · 2026Article
- Giant Magnetostriction in Ferrimagnetic SmFeAngewandte Chemie (International ed. in English) · 2026Article
- β‑BaCOChemistry of materials : a publication of the American Chemical Society · 2026Article
- In Situ XRPD Investigation of Relative Humidity-Induced Lattice Responses in Tetragonal Hen Egg-White Lysozyme.Biomolecules · 2026Article
- Demonstration of a Gandolfi-type attachment for fast high-resolution synchrotron XRD of non-ideal specimens.Scientific reports · 2026Article
- High-throughput X-ray total scattering measurement system at BL04B2 of SPring-8.Journal of synchrotron radiation · 2026Article
- Atomic-scale structure of gadolinium in nanocrystalline fluorapatite from marine sediments.Environmental science. Nano · 2026Article
- Charge Ordering and Incommensurate Modulations in the Metamagnetic Layered Manganese Oxysulfide SrJournal of the American Chemical Society · 2026Article
- NaFeNb(POChemistry of materials : a publication of the American Chemical Society · 2026Article
- Correlating Synthesis, Structure, and Thermal Stability of CuBi Nanowires for Spintronic Applications by Electron Microscopy andACS nano · 2025Article
- Revisiting the structures and phase transitions of PrNiOJournal of applied crystallography · 2025Article
- Exploring humidity effects on polycrystalline human insulin-ligand complexes: preliminary crystallographic insights.Journal of applied crystallography · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Following Phase 2 of the upgrade of the ESRF in which the storage ring was replaced by a new low-emittance ring along with many other facility upgrades, the status of ID22, the high-resolution powder-diffraction beamline, is described. The beamline has an in-vacuum undulator as source providing X-rays in the range 6-75 keV. ID22's principle characteristics include very high angular resolution as a result of the highly collimated and monochromatic beam, coupled with a 13-channel Si 111 multi-analyser stage between the sample and a Dectris Eiger2 X 2M-W CdTe pixel detector. The detector's axial resolution allows recorded 2θ values to be automatically corrected for the effects of axial divergence, resulting in narrower and more-symmetric peaks compared with the previous fixed-axial-slit arrangement. The axial acceptance can also be increased with increasing diffraction angle, thus simultaneously improving the statistical quality of high-angle data. A complementary Perkin Elmer XRD1611 medical-imaging detector is available for faster, lower-resolution data, often used at photon energies of 60-70 keV for pair-distribution function analysis, although this is also possible in high-resolution mode by scanning up to 120° 2θ at 35 keV. There are various sample environments, allowing sample temperatures from 4 K to 1600°C, a capillary cell for non-corrosive gas atmospheres in the range 0-100 bar, and a sample-changing robot that can accommodate 75 capillary samples compatible with the temperature range 80 K to 950°C.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.