Evidence map›Paper›PMID 37461414›Full record

ArticleArXiv2023

Modelling small block aperture in an in-house developed GPU-accelerated Monte Carlo-based dose engine for pencil beam scanning proton therapy.

Hongying Feng, Jason M Holmes, Sujay A Vora, Joshua B Stoker, Martin Bues, William W Wong, Terence S Sio, Robert L Foote, Samir H Patel, Jiajian Shen and 1 more

Abstract readPreprint
In one paragraph

Article in ArXiv, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

11 authors.

Hongying FengDepartment of Radiation Oncology, Mayo Clinic, Phoenix, AZ 85054, USA.
Jason M HolmesDepartment of Radiation Oncology, Mayo Clinic, Phoenix, AZ 85054, USA.
Sujay A VoraDepartment of Radiation Oncology, Mayo Clinic, Phoenix, AZ 85054, USA.
Joshua B StokerDepartment of Radiation Oncology, Mayo Clinic, Phoenix, AZ 85054, USA.
Martin BuesDepartment of Radiation Oncology, Mayo Clinic, Phoenix, AZ 85054, USA.
William W WongDepartment of Radiation Oncology, Mayo Clinic, Phoenix, AZ 85054, USA.
Terence S SioDepartment of Radiation Oncology, Mayo Clinic, Phoenix, AZ 85054, USA.
Robert L FooteDepartment of Radiation Oncology, Mayo Clinic, Rochester, MN 55902, USA.
Samir H PatelDepartment of Radiation Oncology, Mayo Clinic, Phoenix, AZ 85054, USA.
Jiajian ShenDepartment of Radiation Oncology, Mayo Clinic, Phoenix, AZ 85054, USA.
Wei LiuDepartment of Radiation Oncology, Mayo Clinic, Phoenix, AZ 85054, USA.

Funding

4D Robust Optimization in Intensity-Modulated Proton TherapyK25CA168984 · NCI · UNIVERSITY OF TX MD ANDERSON CAN CTR · PI LIU, WEI · 2012 to 2015
$450k
NCI NIH HHS K25 CA168984
6 · The paper itself

Abstract

Purpose: To enhance an in-house graphic-processing-unit (GPU) accelerated virtual particle (VP)-based Monte Carlo (MC) proton dose engine (VPMC) to model aperture blocks in both dose calculation and optimization for pencil beam scanning proton therapy (PBSPT)-based stereotactic radiosurgery (SRS). Methods and Materials: A module to simulate VPs passing through patient-specific aperture blocks was developed and integrated in VPMC based on simulation results of realistic particles (primary protons and their secondaries). To validate the aperture block module, VPMC was first validated by an opensource MC code, MCsquare, in eight water phantom simulations with 3cm thick brass apertures: four were with aperture openings of 1, 2, 3, and 4cm without a range shifter, while the other four were with same aperture opening configurations with a range shifter of 45mm water equivalent thickness. Then, VPMC was benchmarked with MCsquare and RayStation MC for 10 patients with small targets (average volume 8.4 cc with range of 0.4 - 43.3 cc). Finally, 3 typical patients were selected for robust optimization with aperture blocks using VPMC. Results: In the water phantoms, 3D gamma passing rate (2%/2mm/10%) between VPMC and MCsquare was 99.71±0.23%. In the patient geometries, 3D gamma passing rates (3%/2mm/10%) between VPMC/MCsquare and RayStation MC were 97.79±2.21%/97.78±1.97%, respectively. Meanwhile, the calculation time was drastically decreased from 112.45±114.08 seconds (MCsquare) to 8.20±6.42 seconds (VPMC) with the same statistical uncertainties of ~0.5%. The robustly optimized plans met all the dose-volume-constraints (DVCs) for the targets and OARs per our institutional protocols. The mean calculation time for 13 influence matrices in robust optimization by VPMC was 41.6 seconds and the subsequent on-the-fly "trial-and-error" optimization procedure took only 71.4 seconds on average for the selected three patients. Conclusion: VPMC has been successfully enhanced to model aperture blocks in dose calculation and optimization for the PBSPT-based SRS.

Identifiers

PMID37461414
PMCPMC10350098

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.