Evidence map›Paper›PMID 37461032›Full record

ArticleJournal of orthopaedic surgery and research2023

Three-dimensional design custom-made uncemented stem for revision of cemented distal femoral endoprosthesis due to aseptic loosening.

Zhuangzhuang Li, Minxun Lu, Yong Zhou, Li Min, Chongqi Tu

Open access · goldAbstract read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.6field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Zhuangzhuang Li *Department of Orthopedics, Orthopaedic Research Institute, West China Hospital, Sichuan University, No. 37 Guoxue Road, Chengdu, 610041, Sichuan, People's Republic of China.
Minxun Lu *Department of Orthopedics, Orthopaedic Research Institute, West China Hospital, Sichuan University, No. 37 Guoxue Road, Chengdu, 610041, Sichuan, People's Republic of China.
Yong ZhouDepartment of Orthopedics, Orthopaedic Research Institute, West China Hospital, Sichuan University, No. 37 Guoxue Road, Chengdu, 610041, Sichuan, People's Republic of China.
Li MinDepartment of Orthopedics, Orthopaedic Research Institute, West China Hospital, Sichuan University, No. 37 Guoxue Road, Chengdu, 610041, Sichuan, People's Republic of China. minli1204@scu.edu.cn.
Chongqi TuDepartment of Orthopedics, Orthopaedic Research Institute, West China Hospital, Sichuan University, No. 37 Guoxue Road, Chengdu, 610041, Sichuan, People's Republic of China. tucq@scu.edu.cn.
Sichuan University · CNWest China Hospital of Sichuan University · CN

Funding

supported by 1·3·5 project for disciplines of excellence, West China Hospital, Sichuan University ZYJC18036
6 · The paper itself

Abstract

backgroundRevision of cemented distal femoral replacement (DFR) due to aseptic loosening is challenging because of the resultant femoral bone loss. This paper aims to examine the outcomes of three-dimensional (3D) design custom-made uncemented stems for revision.

methodsBetween January 2014 and December 2020, 17 patients received 3D design uncemented stems for revision of loosed cemented DFR. The femoral bone loss was classified into four Grades, and four types of uncemented stems were designed correspondingly. The revision stems were custom-made for each patient by measuring the diameter of the medullary cavity and the anterior curvature of the femur.

resultsThe patient counts with their corresponding Grades of femoral bone loss were as follows: Grade I, 8 patients; Grade II, 5 patients; Grade III, 3 patients; and Grade IV, 1 patient. During the mean follow-up of 80 months, no revision failure was detected. The postoperative radiographic showed that the stem matched the femoral anterior curvature well. The femoral bone defect was completely filled by the 3D design stem in 10 of the 17 cases postoperatively. In the remaining cases, the persistent peri-stem defect was filled or partially restored during the follow-up.

conclusion3D design custom-made uncemented stem created precise, stable, and durable fixation and provided satisfactory clinical outcomes, which seems to be a viable method for cemented DFR revision.

Indexed as

Arthroplasty, Replacement, HipHip ProsthesisBone CementsFemurHumansProsthesis DesignProsthesis FailureReoperationTreatment OutcomeBone Cements3D designAseptic looseningDistal femoral replacementRevisionUncemented stem

Identifiers

PMID37461032
PMCPMC10353082
OpenAlexW4384561877

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.