Evidence map›Paper›PMID 37460819›Full record

ArticleSurgical endoscopy2023

Rescue technique for self-expandable metallic stent placement using ultrathin endoscope after failure of the conventional method in patients with malignant colon obstruction: a multicenter retrospective study.

Tae-Geun Gweon, Chul-Hyun Lim, Jinsu Kim, Dong Hoon Kang, Bo In Lee, Young-Seok Cho

Abstract readMulticenter Study
PubMed Publisher
In one paragraph

Article in Surgical endoscopy, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.6field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 2 countries.

Tae-Geun GweonDepartment of Internal Medicine, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
Chul-Hyun LimDepartment of Internal Medicine, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea. diluck@catholic.ac.kr.ORCID http://orcid.org/0000-0002-8347-8979
Jinsu KimDepartment of Internal Medicine, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea. jinsu23@naver.com.
Dong Hoon KangDepartment of Internal Medicine, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
Bo In LeeDepartment of Internal Medicine, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
Young-Seok ChoDepartment of Internal Medicine, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
The Catholic University of Korea Seoul St. Mary's Hospital · KRSt. Mary's Hospital · USThe Catholic University of Korea Bucheon St. Mary's Hospital · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND AND

aimsSelf-expandable metallic stents (SEMS) can be used to treat malignant colorectal obstruction (MCO). Guidewire insertion to the proximal site of MCO is the most important step for SEMS placement. However, some patients cannot undergo guidewire insertion because of total obstruction or location at anatomically challenging areas. We report a guidewire insertion technique using an ultrathin endoscope (UTE) in patients with MCO in whom conventional SEMS insertion failed.

methodsThis study was a retrospective cohort study conducted at three academic centers in Korea. The medical records of 956 consecutive patients who underwent SEMS placement during 2012-2021 were analyzed. After failing guidewire insertion using a colonoscope, a UTE was inserted. Guidewire insertion was done through the working channel of the UTE. Following guidewire insertion, the endoscope was removed from the patient. While removing the endoscope, the guidewire was advanced to be located at the originally inserted site. Then, the colonoscope was inserted over the guidewire, and SEMS was replaced.

resultsConventional SEMS insertion failed in 75 patients. Of these, guidewire insertion using a UTE was tried in 59 patients. The rate of technical success was 91.5% (54/59). Considering all patients, the overall technical success rate of SEMS placement was 97.8% (935/956). This technique increased the technical success rate by 5.6% among the total cohort.

conclusionsThe UTE facilitated guidewire insertion and enhanced the overall success rate for SEMS placement. In addition, this technique can be used as a rescue method when guidewire insertion fails using a colonoscope.

Indexed as

Intestinal ObstructionSelf Expandable Metallic StentsCephalosporinsColonEndoscopesHumansPalliative CareRetrospective StudiesStentsTreatment OutcomeCephalosporinsMCOColorectal cancerMalignant colorectal obstructionSelf-expandable metal stentUltrathin endoscopy

Identifiers

PMID37460819
OpenAlexW4384562095

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.