Evidence map›Paper›PMID 37460575›Full record

ArticleScientific reports2023

The accuracy and safety of intraoperative ultrasound-guided external ventricular drainage in intraventricular hemorrhage.

Lijun Zhang, Zhaohui Mu, Guoliang Shen, Ming Yang

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.6field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 8 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Lijun Zhang *Department of Neurosurgery, Taizhou First People's Hospital, Taizhou, Zhejiang, 318020, People's Republic of China. zlj940202@163.com.
Zhaohui Mu *Department of Neurosurgery, Taizhou First People's Hospital, Taizhou, Zhejiang, 318020, People's Republic of China.
Guoliang ShenDepartment of Neurosurgery, Taizhou First People's Hospital, Taizhou, Zhejiang, 318020, People's Republic of China.
Ming YangDepartment of Neurosurgery, Taizhou First People's Hospital, Taizhou, Zhejiang, 318020, People's Republic of China.
Taizhou First People's Hospital · CNWenzhou Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Severe IVH often results in a poor outcome. Currently, EVD is a standard treatment for IVH, but there is little research to show whether using ultrasound to guide the catheter placement improves outcome. Patients with severe IVH who had iUS-guided EVD (the iUS-guided group) were enrolled retrospectively and compared with a group who had EVD performed without ultrasound guidance (the control group) from January 2016 to July 2022. Data were collected on accuracy of the catheter placement, complications and outcome at 3 months assessed by mRS. The accuracy of the EVD placement was classified as optimal placement, sub-optimal placement and misplacement according to the position of the catheter tip. The complications reported are catheter-related hemorrhage, intracranial infection and hydrocephalus. There were 105 cases enrolled, with 72 patients in the iUS-guided group having 131 catheters inserted and 33 patients in the group where ultrasound was not used with a total of 59 catheters. 116 (88.55%) were optimally placed, 12 (9.16%) sub-optimal and 3 (2.29%) misplaced in the iUS-guided group, while 25 (42.37%) were in optimally placed, 30 (50.85%) sub-optimal and 4(6.78%) misplaced in the control group. Accuracy of placement was highly significantly improved using ultrasound (P < 0.001). The operation time and the average catheterized time were longer in the iUS-guided group (P < 0.05), but the complication rates were no different between the groups. The mRS at three months was not significantly different between the two groups. Using iUS to place EVD catheters in patients with severe IVH is a safe technique delivering more accurate catheter placement without increasing the complication rate compared with freehand placement.

Indexed as

Cerebral HemorrhageHydrocephalusDrainageHumansRetrospective StudiesTreatment OutcomeUltrasonography, Interventional

Identifiers

PMID37460575
PMCPMC10352289
OpenAlexW4384560553

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.