ArticleIEEE transactions on bio-medical engineering2024
ACT5 Electrical Impedance Tomography System.
Article in IEEE transactions on bio-medical engineering, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed.
- Electrical impedance tomography reveals ventilation and perfusion heterogeneity in infants with bronchopulmonary dysplasia.Journal of perinatology : official journal of the California Perinatal Association · 2026Article
- Feasibility of Electric Impedance Tomography in the Assessment of Lung Perfusion and Ventilation in Congenital Pulmonary Vein Stenosis.Pediatric cardiology · 2026Article
- Electrical impedance tomography imaging of ventilation and perfusion in bronchopulmonary dysplasia.Journal of perinatology : official journal of the California Perinatal Association · 2026Article
- Use of an anatomical atlas in real-time EIT reconstructions of ventilation and pulsatile perfusion in preterm infants.Scientific reports · 2025Article
- Simultaneous Acquisition of EIT and ECG Signals on Active EIT Electrodes.IEEE transactions on bio-medical engineering · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
objectiveThis article introduces the Adaptive Current Tomograph 5 (ACT5) Electrical Impedance Tomography (EIT) system. ACT5 is a 32 electrode applied-current multiple-source EIT system that can display real-time images of conductivity and susceptivity at 27 frames per second. The adaptive current sources in ACT5 can apply fully programmable current patterns with frequencies varying from 5 kHz to 500 kHz. The system also displays real-time ECG readings during the EIT imaging process.
methodsThe hardware and software design and specifications are presented, including the current source design, FPGA hardware, safety features, calibration, and shunt impedance measurement.
resultsImages of conductivity and susceptivity are presented from ACT5 data collected on tank phantoms and a human subject illustrating the system's ability to provide real-time images of pulsatile perfusion and ECG traces. SIGNIFICANCE: The portability, high signal-to-noise ratio, and flexibility of applied currents over a wide range of frequencies enable this instrument to be used to obtain useful human subject data with relative clinical ease.