Evidence map›Paper›PMID 37457868›Full record

ArticleJournal of materials chemistry. C2023

A stable physisorbed layer of packed capture antibodies for high-performance sensing applications.

Lucia Sarcina, Cecilia Scandurra, Cinzia Di Franco, Mariapia Caputo, Michele Catacchio, Paolo Bollella, Gaetano Scamarcio, Eleonora Macchia, Luisa Torsi

Abstract read
In one paragraph

Article in Journal of materials chemistry. C, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Protein Adsorption Kinetics on Silica: Theoretical Modeling and Experiments.Langmuir : the ACS journal of surfaces and colloids · 2026
    Article
  4. Article
  5. Plasmonic Single-Molecule Affinity Detection at 10Advanced materials (Deerfield Beach, Fla.) · 2025
    Article
  6. Electric Field Cycling of Physisorbed Antibodies Reduces Biolayer Polarization Dispersion.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025
    Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Lucia SarcinaDipartimento di Chimica, Università degli Studi di Bari Aldo Moro, Via E. Orabona 4 70125 Bari Italy luisa.torsi@uniba.it.ORCID https://orcid.org/0000-0001-7797-029X
Cecilia ScandurraDipartimento di Chimica, Università degli Studi di Bari Aldo Moro, Via E. Orabona 4 70125 Bari Italy luisa.torsi@uniba.it.ORCID https://orcid.org/0000-0002-6085-1910
Cinzia Di FrancoCNR - Institute of Photonics and Nanotechnologies 70126 Bari Italy.
Mariapia CaputoDipartimento di Farmacia-Scienze del Farmaco, Università degli Studi di Bari Aldo Moro 70126 Bari Italy eleonora.macchia@uniba.it.ORCID https://orcid.org/0000-0002-9390-293X
Michele CatacchioDipartimento di Farmacia-Scienze del Farmaco, Università degli Studi di Bari Aldo Moro 70126 Bari Italy eleonora.macchia@uniba.it.
Paolo BollellaDipartimento di Chimica, Università degli Studi di Bari Aldo Moro, Via E. Orabona 4 70125 Bari Italy luisa.torsi@uniba.it.ORCID https://orcid.org/0000-0001-9049-6406
Gaetano ScamarcioDipartimento Interateneo di Fisica "M. Merlin", Università degli Studi di Bari Aldo Moro 70126 Bari Italy.
Eleonora MacchiaDipartimento di Farmacia-Scienze del Farmaco, Università degli Studi di Bari Aldo Moro 70126 Bari Italy eleonora.macchia@uniba.it.ORCID https://orcid.org/0000-0002-1534-7336
Luisa TorsiDipartimento di Chimica, Università degli Studi di Bari Aldo Moro, Via E. Orabona 4 70125 Bari Italy luisa.torsi@uniba.it.ORCID https://orcid.org/0000-0002-0798-0780

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Antibody physisorption at a solid interface is a very interesting phenomenon that has important effects on applications such as the development of novel biomaterials and the rational design and fabrication of high-performance biosensors. The strategy selected to immobilize biorecognition elements can determine the performance level of a device and one of the simplest approaches is physical adsorption, which is cost-effective, fast, and compatible with printing techniques as well as with green-chemistry processes. Despite its huge advantages, physisorption is very seldom adopted, as there is an ingrained belief that it does not lead to high performance because of its lack of uniformity and long-term stability, which, however, have never been systematically investigated, particularly for bilayers of capture antibodies. Herein, the homogeneity and stability of an antibody layer against SARS-CoV-2-Spike1 (S1) protein physisorbed onto a gold surface have been investigated by means of multi-parametric surface plasmon resonance (MP-SPR). A surface coverage density of capture antibodies as high as (1.50 ± 0.06) × 10

Identifiers

PMID37457868
PMCPMC10341389

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.