Evidence map›Paper›PMID 37457824›Full record

ArticleAdvances in radiation oncology

Development and Dosimetric Characterization of a Customizable Shield for Subtotal Skin Electron Beam Therapy.

J John Lucido, Gregory P Penoncello, Brady S Laughlin, Michael D Armstrong, Stephanie G Lo, Judith N Rivera, Xueyan Tang, Suzanne J Chungbin, William G Breen, Aaron R Mangold and 5 more

Open access · goldAbstract read
In one paragraph

Article in Advances in radiation oncology. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.6field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

15 authors at 4 institutions in 1 country.

J John LucidoDepartment of Radiation Oncology, Mayo Clinic, Rochester, Minnesota.
Gregory P PenoncelloDepartment of Radiation Oncology, University of Colorado, Aurora, Colorado.
Brady S LaughlinDepartment of Radiation Oncology, Mayo Clinic, Phoenix, Arizona.
Michael D ArmstrongDepartment of Radiation Oncology, Mayo Clinic, Phoenix, Arizona.
Stephanie G LoDepartment of Radiation Oncology, Mayo Clinic, Rochester, Minnesota.
Judith N RiveraDepartment of Radiation Oncology, Mayo Clinic, Rochester, Minnesota.
Xueyan TangDepartment of Radiation Oncology, Mayo Clinic, Rochester, Minnesota.
Suzanne J ChungbinDepartment of Radiation Oncology, Mayo Clinic, Phoenix, Arizona.
William G BreenDepartment of Radiation Oncology, Mayo Clinic, Rochester, Minnesota.
Aaron R MangoldDepartment of Dermatology, Mayo Clinic, Phoenix, Arizona.
Nneka I ComfereDepartment of Dermatology, Mayo Clinic, Rochester, Minnesota.
Scott C LesterDepartment of Radiation Oncology, Mayo Clinic, Rochester, Minnesota.
William G RuleDepartment of Radiation Oncology, Mayo Clinic, Phoenix, Arizona.
Christopher L DeufelDepartment of Radiation Oncology, Mayo Clinic, Rochester, Minnesota.
Madeline G FosterDepartment of Radiation Oncology, Mayo Clinic, Phoenix, Arizona.
Mayo Clinic · USMayo Clinic in Florida · USUniversity of Colorado Anschutz Medical Campus · USWinnMed · US

Funding

Women's Cancer ProgramP30CA015083 · NCI · MAYO CLINIC ROCHESTER · PI Felicity Enders · 1985 to 2026
$151.3M
NCI NIH HHS P30 CA015083
6 · The paper itself

Abstract

Purpose: Purpose: Subtotal skin electron beam therapy may be an option for patients with cutaneous lymphoma receiving radiation therapy to treat large areas of their skin but may benefit from sparing specific areas that may have had previous radiation therapy, are of specific cosmetic concern, and/or show no evidence of disease. We report here on the design, implementation, and dosimetric characteristics of a reusable and transparent customizable shield for use with the large fields used to deliver total skin electron beam therapy at extended distance with a conventional linear accelerator. Methods and Materials: A shield was designed and manufactured consisting of acrylic blocks that can be mounted on a steel frame to allow patient-specific shielding. The dosimetry of the device was measured using radiochromic film. Results: The shield is easy to use and well-tolerated for patient treatment, providing minimal electron transmission through the shield with a sharp penumbra at the field edge, with no increase in x-ray dose. We report on the dosimetry of a commercial device that has been used to treat more than 30 patients to date. Conclusions: The customizable shield is well suited to providing patient-specific shielding for subtotal skin electron beam therapy.

Identifiers

PMID37457824
PMCPMC10344686
OpenAlexW4380990366

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.