ArticleQuantitative imaging in medicine and surgery2023
Synthetic high-energy computed tomography image via a Wasserstein generative adversarial network with the convolutional block attention module.
Article in Quantitative imaging in medicine and surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Computed tomography (CT) is now universally applied into clinical practice with its non-invasive quality and reliability for lesion detection, which highly improves the diagnostic accuracy of patients with systemic diseases. Although low-dose CT reduces X-ray radiation dose and harm to the human body, it inevitably produces noise and artifacts that are detrimental to information acquisition and medical diagnosis for CT images. Methods: This paper proposes a Wasserstein generative adversarial network (WGAN) with a convolutional block attention module (CBAM) to realize a method of directly synthesizing high-energy CT (HECT) images through low-energy scanning, which greatly reduces X-ray radiation from high-energy scanning. Specifically, our proposed generator structure in WGAN consists of Visual Geometry Group Network (Vgg16), 9 residual blocks, upsampling and CBAM, a subsequent attention block. The convolutional block attention module is integrated into the generator for improving the denoising ability of the network as verified by our ablation comparison experiments. Results: Experimental results of the generator attention module ablation comparison indicate an optimization boost to the overall generator model, obtaining the synthesized high-energy CT with the best metric and denoising effect. In different methods comparison experiments, it can be clearly observed that our proposed method is superior in the peak signal-to-noise ratio (PSNR), structural similarity index measure (SSIM) and most of the statistics (average CT value and its standard deviation) compared to other methods. Because P<0.05, the samples are significantly different. The data distribution at the pixel level between the images synthesized by the method in this paper and the high-energy CT images is also most similar. Conclusions: Experimental results indicate that CBAM is able to suppress the noise and artifacts effectively and suggest that the image synthesized by the proposed method is closest to the high-energy CT image in terms of visual perception and objective evaluation metrics.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.