Evidence map›Paper›PMID 37455915›Full record

ArticleFrontiers in endocrinology2023

Comparison of computed tomography and dual-energy X-ray absorptiometry in the evaluation of body composition in patients with obesity.

Fiorella Palmas, Andreea Ciudin, Raul Guerra, Daniel Eiroa, Carina Espinet, Nuria Roson, Rosa Burgos, Rafael Simó

Open access · goldAbstract read
In one paragraph

Article in Frontiers in endocrinology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
3.2field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 18 citations in OpenAlex.

  1. Review
  2. Review
  3. Article
  4. Observational
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Observational
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 1 country.

Fiorella PalmasEndocrinology and Nutrition Department, Hospital Universitari Vall D´Hebron, Barcelona, Spain.
Andreea CiudinEndocrinology and Nutrition Department, Hospital Universitari Vall D´Hebron, Barcelona, Spain.
Raul GuerraARTIS Development, Las Palmas, Spain.
Daniel EiroaDepartment of Radiology, Institut De Diagnòstic Per La Imatge (IDI), Hospital Universitari Vall d'Hebron, Barcelona, Spain.
Carina EspinetNuclear Medicine Deparment, Vall Hebron Hospital, Barcelona, Spain.
Nuria RosonDepartment of Radiology, Institut De Diagnòstic Per La Imatge (IDI), Hospital Universitari Vall d'Hebron, Barcelona, Spain.
Rosa BurgosEndocrinology and Nutrition Department, Hospital Universitari Vall D´Hebron, Barcelona, Spain.
Rafael SimóEndocrinology and Nutrition Department, Hospital Universitari Vall D´Hebron, Barcelona, Spain.
Vall d'Hebron Hospital Universitari · ESCentro de Investigación Biomédica en Red Diabetes y Enfermedades Metabólicas Asociadas · ESUniversitat Autònoma de Barcelona · ESVall d'Hebron Institut de Recerca · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: a) To evaluate the accuracy of the pre-existing equations (based on cm2 provided by CT images), to estimate in kilograms (Kg) the body composition (BC) in patients with obesity (PwO), by comparison with Dual-energy X-ray absorptiometry (DXA). b) To evaluate the accuracy of a new approach (based on both cm2 and Hounsfield Unit parameters provided by CT images), using an automatic software and artificial intelligence to estimate the BC in PwO, by comparison with DXA. Methods: Single-centre cross-sectional study including consecutive PwO, matched by gender with subjects with normal BMI. All the subjects underwent BC assessment by Dual-energy X-ray absorptiometry (DXA) and skeletal-CT at L3 vertebrae. CT images were processed using FocusedON-BC software. Three different models were tested. Model 1 and 2, based on the already existing equations, estimate the BC in Kg based on the tissue area (cm2) in the CT images. Model 3, developed in this study, includes as additional variables, the tissue percentage and its average Hounsfield unit. Results: 70 subjects (46 PwO and 24 with normal BMI) were recruited. Significant correlations for BC were obtained between the three models and DXA. Model 3 showed the strongest correlation with DXA (r= 0.926, CI95% [0.835-0.968], p<0.001) as well as the best agreement based on Bland - Altman plots. Conclusion: This is the first study showing that the BC assessment based on skeletal CT images analyzed by automatic software coupled with artificial intelligence, is accurate in PwO, by comparison with DXA. Furthermore, we propose a new equation that estimates both the tissue quantity and quality, that showed higher accuracy compared with those currently used, both in PwO and subjects with normal BMI.

Indexed as

Artificial IntelligenceBody CompositionAbsorptiometry, PhotonCross-Sectional StudiesHumansObesityTomography, X-Ray Computedbody compositioncomputed tomographydual-energy X-ray absorptiometrymorbid obesityobesity

Identifiers

PMID37455915
PMCPMC10345841
OpenAlexW4382584214

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.