Evidence map›Paper›PMID 37450176›Full record

ArticleInternational journal of computer assisted radiology and surgery2024

Automated quantification of glenoid bone loss in CT scans for shoulder dislocation surgery planning.

Avichai Haimi, Shaul Beyth, Moshe Gross, Ori Safran, Leo Joskowicz

Abstract read
PubMed Publisher
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.3field-weighted citation impact, top 40% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Avichai HaimiSchool of Computer Science and Engineering, The Hebrew University of Jerusalem, Edmond J. Safra Campus, Givat Ram, 9190401, Jerusalem, Israel.
Shaul BeythDepartment of Orthopedics, Hadassah Medical Center, Faculty of Medicine, Hebrew University of Jerusalem, Jerusalem, Israel.
Moshe GrossDepartment of Orthopedics, Hadassah Medical Center, Faculty of Medicine, Hebrew University of Jerusalem, Jerusalem, Israel.
Ori Safran *Department of Orthopedics, Hadassah Medical Center, Faculty of Medicine, Hebrew University of Jerusalem, Jerusalem, Israel.
Leo Joskowicz *School of Computer Science and Engineering, The Hebrew University of Jerusalem, Edmond J. Safra Campus, Givat Ram, 9190401, Jerusalem, Israel. josko@cs.huji.ac.il.ORCID http://orcid.org/0000-0002-3010-4770
Hebrew University of Jerusalem · IL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeEstimation of glenoid bone loss in CT scans following shoulder dislocation is required to determine the type of surgery needed to restore shoulder stability. This paper presents a novel automatic method for the computation of glenoid bone loss in CT scans.

methodsThe model-based method is a pipeline that consists of four steps: (1) computation of an oblique plane in the CT scan that best matches the glenoid face orientation; (2) selection of the glenoid oblique CT slice; (3) computation of the circle that best fits the posteroinferior glenoid contour; (4) quantification of the glenoid bone loss. The best-fit circle is computed with newly defined Glenoid Clock Circle Constraints.

resultsThe pipeline and each of its steps were evaluated on 51 shoulder CT scans (44 patients). Ground truth oblique slice, best-fit circle, and glenoid bone loss measurements were obtained manually from three clinicians. The full pipeline yielded a mean absolute error (%) for the bone loss deficiency of 2.3 ± 2.9 mm (4.67 ± 3.32%). The mean oblique CT slice selection difference was 1.42 ± 1.32 slices, above the observer variability of 1.74 ± 1.82 slices. The glenoid bone loss deficiency measure (%) on the ground truth oblique glenoid CT slice has a mean average error of 0.54 ± 1.03 mm (4.76 ± 3.00%), close to the observer variability of 0.93 ± 1.40 mm (2.98 ± 4.97%).

conclusionOur pipeline is the first fully automatic method for the quantitative analysis of glenoid bone loss in CT scans. The computed glenoid bone loss report may assist orthopedists in selecting and planning surgical shoulder dislocation procedures.

Indexed as

Joint InstabilityShoulder DislocationShoulder JointHumansScapulaTomography, X-Ray ComputedComputed tomography (CT) scansGlenoid bone lossShoulder dislocationSurgical decision support

Identifiers

PMID37450176
OpenAlexW4384301042