ArticleEJNMMI physics2023
A time-based double-sided readout concept of 100 mm LYSO:Ce,Ca fibres for future axial TOF-PET.
Article in EJNMMI physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 15 citations in OpenAlex.
- Advancements in DOI-capable TOF-PET modules using a multi-channel high-frequency readout.EJNMMI physics · 2026Article
- Image reconstruction and elongation artifact reduction for a dual-panel dedicated prostate PET scanner.Medical physics · 2026Article
- Optical crosstalk between SiPMs in dual-ended readout.Sensors and actuators. A, Physical · 2025Article
- High-performance dual-ended SiPM readout for TOF-PET with BGO and LYSO:Ce.IEEE transactions on radiation and plasma medical sciences · 2025Article
- ASICs in PET: what we have and what we need.EJNMMI physics · 2025Review
- PET detectors with depth-of-interaction and time-of-flight capabilities.Radiological physics and technology · 2024Review
- 16-channel SiPM high-frequency readout with time-over-threshold discrimination for ultrafast time-of-flight applications.EJNMMI physics · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
Abstract
backgroundPositron emission tomography (PET) requires a high signal-to-noise ratio (SNR) to improve image quality, with time-of-flight (TOF) being an effective way to boost the SNR. However, the scanner sensitivity and resolution must be maintained. The use of axially aligned 100-mm LYSO:Ce,Ca scintillation crystals with double-sided readout has the potential of ground-breaking TOF and sensitivity, while reducing parallax errors through depth-of-interaction (DOI) estimation, and also allowing a reduction in the number of readout channels required, resulting in cost benefits. Due to orientation, these fibres may also facilitate the integration of TOF-PET with magnetic resonance imaging (MRI) in hybrid imaging systems. The challenge of achieving a good spatial resolution with such long axial fibres is directly related to the achievable TOF resolution. In this study, the timing performance and DOI resolution of emerging high-performance materials were investigated to assess the merits of this approach in organ-dedicated or total-body/large-scale PET imaging systems.
methodsLYSO:Ce,Ca scintillation fibres of 20 mm and 100 mm length were tested in various operating and readout configurations to determine the best achievable coincidence time resolution (CTR) and DOI resolution. The tests were performed using state-of-the-art high-frequency (HF) readout and commercially available silicon photomultipliers (SiPMs) from Broadcom Inc.
resultsFor the 100-mm fibre, an average CTR performance of [Formula: see text] ps FWHM and an average depth-of-interaction resolution within the fibre of [Formula: see text] mm FWHM could be obtained. The 20-mm fibre showed a sub-100 ps CTR of [Formula: see text] ps FWHM and a fibre resolution of [Formula: see text] mm FWHM in the double-sided readout configuration.
conclusionWith modern SiPMs and crystals, a double-sided readout of long fibres can achieve excellent timing resolution and field-advancing TOF resolution, outperforming commercial PET systems. With 100-mm fibres, an electronic channel reduction of about a factor 2.5 is inherent, with larger reduction factors conceivable, which can lead to lower production costs. The spatial resolution was shown to be limited in the axial direction with 12 mm, but is defined to 3 mm in all other directions. Recent SiPM and scintillator developments are expected to improve on the time and spatial resolution to be investigated in future prototypes.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.