ArticleResuscitation plus2023
Hands-free continuous carotid Doppler ultrasound for detection of the pulse during cardiac arrest in a porcine model.
Article in Resuscitation plus, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 3 registered trials, which are not on this map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
A Feasibility Study to Evaluate a New Doppler Method (RescueDoppler) for Monitoring Blood Flow in the Carotid Artery in Subjects Suffering From Sudden Cardiac Arrest
Clinical Validation of a Novel Ultrasound Probe (RescueDoppler) During Physiological Perturbations and Initiation Of- and Weaning from Cardiopulmonary Bypass in Adult, Cardiac Surgery Patients
Pulse Detection in Cardiac Arrest Patients Using a Doppler Ultrasound Patch on the Carotid Artery
Who cites it
8 citing papers in PubMed, 7 citations in OpenAlex.
- Serial Ultrasound-Guided Carotid Artery Compression During Chest Compressions for Assessing Circulatory Status: A Prospective Pilot Diagnostic Study.Diagnostics (Basel, Switzerland) · 2026Article
- Detection of return of spontaneous circulation during cardiopulmonary resuscitation using continuous carotid artery Doppler blood flow monitored by AI in an animal model.Resuscitation plus · 2026Article
- Using a Stifneck Select CollarTM for hands-free semiautomatic blood flow measurements: A user study.PloS one · 2026Article
- Realtime detection of spontaneous circulation in humans during cardiopulmonary resuscitation using a continuous hands-free carotid Doppler: a pilot study.Resuscitation plus · 2025Article
- Re-arrest immediately after return of spontaneous circulation: A retrospective observational study of in-hospital cardiac arrest.Acta anaesthesiologica Scandinavica · 2025Observational
- A hands-free carotid Doppler can identify spontaneous circulation without interrupting cardiopulmonary resuscitation: an animal study.Intensive care medicine experimental · 2024Article
- Evaluation of hemorrhagic shock and fluid resuscitation in pigs using handless Doppler carotid artery ultrasound.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2024Article
- Real-time feedback on chest compression efficacy by hands-free carotid Doppler in a porcine model.Resuscitation plus · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 4 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background/Purpose: Pulse palpation is an unreliable method for diagnosing cardiac arrest. To address this limitation, continuous hemodynamic monitoring may be a viable solution. Therefore, we developed a novel, hands-free Doppler system, RescueDoppler, to detect the pulse continuously in the carotid artery. Methods: In twelve pigs, we evaluated RescueDoppleŕs potential to measure blood flow velocity in three situations where pulse palpation of the carotid artery was insufficient: (1) systolic blood pressure below 60 mmHg, (2) ventricular fibrillation (VF) and (3) pulseless electrical activity (PEA). (1) Low blood pressure was induced using a Fogarty balloon catheter to occlude the inferior vena cava. (2) An implantable cardioverter-defibrillator induced VF. (3) Myocardial infarction after microembolization of the left coronary artery caused True-PEA. Invasive blood pressure was measured in the contralateral carotid artery. Time-averaged blood flow velocity (TAV) in the carotid artery was related to mean arterial pressure (MAP) in a linear mixed model. Results: RescueDoppler identified pulsatile blood flow in 41/41 events with systolic blood pressure below 60 mmHg, with lowest blood pressure of 19 mmHg. In addition the absence of spontaneous circulation was identified in 21/21 VF events and true PEA in 2/2 events. The intraclass correlation coefficient within animals for TAV and MAP was 0.94 (95% CI. 0.85-0.98). Conclusions: In a porcine model, RescueDoppler reliably identified pulsative blood flow with blood pressures below 60 mmHg. During VF and PEA, circulatory arrest was rapidly and accurately demonstrated. RescueDoppler could potentially replace unreliable pulse palpation during cardiac arrest and cardiopulmonary resuscitation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.