Evidence map›Paper›PMID 37447997›Full record

ArticleSensors (Basel, Switzerland)2023

Paintable Silicone-Based Corrugated Soft Elastomeric Capacitor for Area Strain Sensing.

Han Liu, Simon Laflamme, Matthias Kollosche

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Han LiuDepartment of Civil, Construction, and Environmental Engineering, Iowa State University, Ames, IA 50011, USA.ORCID 0000-0003-3057-522X
Simon LaflammeDepartment of Civil, Construction, and Environmental Engineering, Iowa State University, Ames, IA 50011, USA.ORCID 0000-0002-0601-9664
Matthias KolloscheDepartment of Civil, Construction, and Environmental Engineering, Iowa State University, Ames, IA 50011, USA.

Funding

Departments of Transportation of Iowa, Kansas, South Carolina, and North Carolina Pooled Fund Study TPF-5(449)
6 · The paper itself

Abstract

Recent advances in soft polymer materials have enabled the design of soft machines and devices at multiple scales. Their intrinsic compliance and robust mechanical properties and the potential for a rapid scaling of the production process make them ideal candidates for flexible and stretchable electronics and sensors. Large-area electronics (LAE) made from soft polymer materials that are capable of sustaining large deformations and covering large surfaces and are applicable to complex and irregular surfaces and transducing deformations into readable signals have been explored for structural health monitoring (SHM) applications. The authors have previously proposed and developed an LAE consisting of a corrugated soft elastomeric capacitor (cSEC). The corrugation is used to engineer the directional strain sensitivity by using a thermoplastic styrene-ethylene-butadiene-styrene (SEBS). A key limitation of the SEBS-cSEC technology is the need of an epoxy for reliable bonding of the sensor onto the monitored surface, mainly attributable to the sensor's fabrication process that comprises a solvent that limits its direct deployment through a painting process. Here, with the objective to produce a paintable cSEC, we study an improved solvent-free fabrication method by using a commercial room-temperature-vulcanizing silicone as the host matrix. The matrix is filled with titania particles to form the dielectric layer, yielding a permittivity of 4.05. Carbon black powder is brushed onto the dielectric and encapsulated with the same silicone to form the conductive stretchable electrodes. The sensor is deployed by directly painting a layer of the silicone onto the monitored surface and then depositing the parallel plate capacitor. The electromechanical behavior of the painted silicone-cSEC was characterized and exhibited good linearity, with an R2 value of 0.9901, a gauge factor of 1.58, and a resolution of 70 με. This resolution compared well with that of the epoxied SEBS-cSEC reported in previous work (25 με). Its performance was compared against that of its more mature version, the SEBS-cSEC, in a network configuration on a cantilever plate subjected to a step-deformation and to free vibrations. Results showed that the performance of the painted silicone-sCEC compared well with that of the SEBS-cSEC, but that the use of a silicone paint instead of an epoxy could be responsible for larger noise and the under-estimation of the dominating frequency by 6.7%, likely attributable to slippage.

Indexed as

Bone PlatesSilicone ElastomersElectric ConductivityElectrodesEpoxy ResinsStyrenesEpoxy ResinsSilicone ElastomersStyrenescompositeflexible sensorlarge area electronicspolymersiliconesoft elastomeric capacitorstrainstretchable sensorstructural health monitoring

Identifiers

PMID37447997
PMCPMC10346726

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.