Evidence map›Paper›PMID 37447992›Full record

ArticleSensors (Basel, Switzerland)2023

Assessing the Feasibility of Replacing Subjective Questionnaire-Based Sleep Measurement with an Objective Approach Using a Smartwatch.

Maksym Gaiduk, Ralf Seepold, Natividad Martínez Madrid, Juan Antonio Ortega

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Maksym GaidukDepartment of Computer Science, HTWG Konstanz-University of Applied Sciences, 78462 Konstanz, Germany.ORCID 0000-0001-9607-5709
Ralf SeepoldDepartment of Computer Science, HTWG Konstanz-University of Applied Sciences, 78462 Konstanz, Germany.ORCID 0000-0002-5192-2537
Natividad Martínez MadridSchool of Informatics, Reutlingen University, 72762 Reutlingen, Germany.ORCID 0000-0003-1965-9481
Juan Antonio OrtegaSchool of Computer Engineering, University of Seville, 41012 Seville, Spain.ORCID 0000-0001-9095-7241

Funding

Carl Zeiss Foundation P2019-03-003Open Access Publication Fund of the HTWG Hochschule 597 Konstanz University of Applied Sciences
6 · The paper itself

Abstract

In order to ensure sufficient recovery of the human body and brain, healthy sleep is indispensable. For this purpose, appropriate therapy should be initiated at an early stage in the case of sleep disorders. For some sleep disorders (e.g., insomnia), a sleep diary is essential for diagnosis and therapy monitoring. However, subjective measurement with a sleep diary has several disadvantages, requiring regular action from the user and leading to decreased comfort and potential data loss. To automate sleep monitoring and increase user comfort, one could consider replacing a sleep diary with an automatic measurement, such as a smartwatch, which would not disturb sleep. To obtain accurate results on the evaluation of the possibility of such a replacement, a field study was conducted with a total of 166 overnight recordings, followed by an analysis of the results. In this evaluation, objective sleep measurement with a Samsung Galaxy Watch 4 was compared to a subjective approach with a sleep diary, which is a standard method in sleep medicine. The focus was on comparing four relevant sleep characteristics: falling asleep time, waking up time, total sleep time (TST), and sleep efficiency (SE). After evaluating the results, it was concluded that a smartwatch could replace subjective measurement to determine falling asleep and waking up time, considering some level of inaccuracy. In the case of SE, substitution was also proved to be possible. However, some individual recordings showed a higher discrepancy in results between the two approaches. For its part, the evaluation of the TST measurement currently does not allow us to recommend substituting the measurement method for this sleep parameter. The appropriateness of replacing sleep diary measurement with a smartwatch depends on the acceptable levels of discrepancy. We propose four levels of similarity of results, defining ranges of absolute differences between objective and subjective measurements. By considering the values in the provided table and knowing the required accuracy, it is possible to determine the suitability of substitution in each individual case. The introduction of a "similarity level" parameter increases the adaptability and reusability of study findings in individual practical cases.

Indexed as

SleepSleep Wake DisordersFeasibility StudiesHumansPolysomnographySurveys and Questionnairesobjective and subjective sleep measurementsleep diarysleep studysmartwatchwearables

Identifiers

PMID37447992
PMCPMC10346325

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.