Evidence map›Paper›PMID 37447968›Full record

ArticleSensors (Basel, Switzerland)2023

Group Method of Data Handling Using Christiano-Fitzgerald Random Walk Filter for Insulator Fault Prediction.

Stefano Frizzo Stefenon, Laio Oriel Seman, Nemesio Fava Sopelsa Neto, Luiz Henrique Meyer, Viviana Cocco Mariani, Leandro Dos Santos Coelho

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
5.9field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 34 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 2 countries.

Stefano Frizzo StefenonDigital Industry Center, Fondazione Bruno Kessler, 38123 Trento, Italy.ORCID 0000-0002-3723-616X
Laio Oriel SemanGraduate Program in Applied Computer Science, University of Vale do Itajai, Itajai 88302-901, SC, Brazil.ORCID 0000-0002-6806-9122
Nemesio Fava Sopelsa NetoElectrical Engineering Graduate Program, Regional University of Blumenau, Blumenau 89030-000, SC, Brazil.
Luiz Henrique MeyerElectrical Engineering Graduate Program, Regional University of Blumenau, Blumenau 89030-000, SC, Brazil.ORCID 0000-0003-0569-2416
Viviana Cocco MarianiMechanical Engineering Graduate Program, Pontifical Catholic University of Parana, Curitiba 80215-901, PR, Brazil.ORCID 0000-0003-2490-4568
Leandro Dos Santos CoelhoDepartment of Electrical Engineering, Federal University of Parana, Curitiba 81530-000, PR, Brazil.ORCID 0000-0001-5728-943X
Pontifícia Universidade Católica do Paraná · BRUniversidade Regional de Blumenau · BRUniversidade do Vale do Itajaí · BRUniversity of Udine · IT

Funding

Fundação Araucária PRONEX 042/2018National Council for Scientific and Technological Development 307958/2019-1-PQNational Council for Scientific and Technological Development 307966/2019-4-PQNational Council for Scientific and Technological Development 308361/2022-9National Council for Scientific and Technological Development 408164/2021-2-Universal
6 · The paper itself

Abstract

Disruptive failures threaten the reliability of electric supply in power branches, often indicated by the rise of leakage current in distribution insulators. This paper presents a novel, hybrid method for fault prediction based on the time series of the leakage current of contaminated insulators. In a controlled high-voltage laboratory simulation, 15 kV-class insulators from an electrical power distribution network were exposed to increasing contamination in a salt chamber. The leakage current was recorded over 28 h of effective exposure, culminating in a flashover in all considered insulators. This flashover event served as the prediction mark that this paper proposes to evaluate. The proposed method applies the Christiano-Fitzgerald random walk (CFRW) filter for trend decomposition and the group data-handling (GMDH) method for time series prediction. The CFRW filter, with its versatility, proved to be more effective than the seasonal decomposition using moving averages in reducing non-linearities. The CFRW-GMDH method, with a root-mean-squared error of 3.44×10-12, outperformed both the standard GMDH and long short-term memory models in fault prediction. This superior performance suggested that the CFRW-GMDH method is a promising tool for predicting faults in power grid insulators based on leakage current data. This approach can provide power utilities with a reliable tool for monitoring insulator health and predicting failures, thereby enhancing the reliability of the power supply.

Indexed as

Computer SystemsDrug ContaminationComputer SimulationElectric Power SuppliesReproducibility of ResultsChristiano–Fitzgerald random walk filterelectrical power gridsgroup method of data handlingleakage currenttime series forecasting

Identifiers

PMID37447968
PMCPMC10346365
OpenAlexW4382936427

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.