Evidence map›Paper›PMID 37447918›Full record

ArticleSensors (Basel, Switzerland)2023

Comparative Evaluations on Real-Time Monitoring of Temperature Sensors during Endoscopic Laser Application.

Minh Duc Ta, Van Gia Truong, Seonghee Lim, Byeong-Il Lee, Hyun Wook Kang

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.9field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Minh Duc TaIndustry 4.0 Convergence Bionics Engineering, Marine-Integrated Biomedical Technology Center, Pukyong National University, Busan 48513, Republic of Korea.
Van Gia TruongTeCure, Inc., Busan 48548, Republic of Korea.
Seonghee LimIndustry 4.0 Convergence Bionics Engineering, Marine-Integrated Biomedical Technology Center, Pukyong National University, Busan 48513, Republic of Korea.
Byeong-Il LeeIndustry 4.0 Convergence Bionics Engineering, Marine-Integrated Biomedical Technology Center, Pukyong National University, Busan 48513, Republic of Korea.
Hyun Wook KangIndustry 4.0 Convergence Bionics Engineering, Marine-Integrated Biomedical Technology Center, Pukyong National University, Busan 48513, Republic of Korea.ORCID 0000-0002-0861-1354
Pukyong National University · KR

Funding

Korea Medical Device Development Fund 202016B01National Research Foundation of Korea 2021R1A6A1A03039211
6 · The paper itself

Abstract

Temperature sensors, such as Fiber Bragg Grating (FBG) and thermocouple (TC), have been widely used for monitoring the interstitial tissue temperature during laser irradiation. The aim of the current study was to compare the performance of both FBG and TC in real-time temperature monitoring during endoscopic and circumferential laser treatment on tubular tissue structure. A 600-µm core-diameter diffusing applicator was employed to deliver 980-nm laser light (30 W for 90 s) circumferentially for quantitative evaluation. The tip of the TC was covered with a white tube (W-TC) in order to prevent direct light absorption and to minimize temperature overestimation. The temperature measurements in air demonstrated that the measurement difference in the temperature elevations was around 3.5 °C between FBG and W-TC. Ex vivo porcine liver tests confirmed that the measurement difference became lower (less than 1 °C). Ex vivo porcine esophageal tissue using a balloon-integrated catheter exhibited that both FBG and W-TC consistently showed a comparable trend of temperature measurements during laser irradiation (~2 °C). The current study demonstrated that the white tube-covered TC could be a feasible sensor to monitor interstitial tissue temperature with minimal overestimation during endoscopic laser irradiation. Further in vivo studies on gastroesophageal reflux disease will investigate the performance of the W-TC to monitor the temperature of the esophageal mucosa surface in real-time mode to warrant the safety of endoscopic laser treatment.

Indexed as

Hyperthermia, InducedAnimalsLasersLightOptical FibersSwineTemperaturediffusing fiberFiber Bragg Gratingthermal coagulationthermocouple

Identifiers

PMID37447918
PMCPMC10346888
OpenAlexW4382982410

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.