Evidence map›Paper›PMID 37447908›Full record

ArticleSensors (Basel, Switzerland)2023

Estimation of Spatiotemporal Gait Parameters in Walking on a Photoelectric System: Validation on Healthy Children by Standard Gait Analysis.

Silvia Campagnini, Guido Pasquini, Florian Schlechtriem, Giulia Fransvea, Laura Simoni, Filippo Gerli, Federica Magaldi, Giovanna Cristella, Robert Riener, Maria Chiara Carrozza and 1 more

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Silvia CampagniniIRCCS Fondazione Don Carlo Gnocchi ONLUS, 50143 Firenze, Italy.ORCID 0000-0001-5732-1399
Guido PasquiniIRCCS Fondazione Don Carlo Gnocchi ONLUS, 50143 Firenze, Italy.ORCID 0000-0002-1811-102X
Florian SchlechtriemDepartment of Health Sciences and Technology, ETH Zurich, 8092 Zurich, Switzerland.
Giulia FransveaIRCCS Fondazione Don Carlo Gnocchi ONLUS, 50143 Firenze, Italy.ORCID 0000-0003-2442-6340
Laura SimoniIRCCS Fondazione Don Carlo Gnocchi ONLUS, 50143 Firenze, Italy.
Filippo GerliIRCCS Fondazione Don Carlo Gnocchi ONLUS, 50143 Firenze, Italy.
Federica MagaldiIRCCS Fondazione Don Carlo Gnocchi ONLUS, 50143 Firenze, Italy.
Giovanna CristellaIRCCS Fondazione Don Carlo Gnocchi ONLUS, 50143 Firenze, Italy.ORCID 0000-0002-5021-7799
Robert RienerDepartment of Health Sciences and Technology, ETH Zurich, 8092 Zurich, Switzerland.
Maria Chiara CarrozzaThe BioRobotics Institute, Scuola Superiore Sant'Anna, 56025 Pisa, Italy.
Andrea ManniniIRCCS Fondazione Don Carlo Gnocchi ONLUS, 50143 Firenze, Italy.ORCID 0000-0003-0760-052X

Funding

Italian Ministry of Health "5x1000 A.F.2018 project"Italian Ministry of Health "5x1000 A.F.2019 project"Italian Ministry of Health "Ricerca Corrente RC2020-2022"Italian Ministry of University "TRAINED project _ PRIN 2017 grant number 2017L2RLZ2"Italian neuroscience and neurorehabilitation research hospitals network "Rete IRCCS delle Neuroscienze e della Neuroriabilitazione"
6 · The paper itself

Abstract

The use of stereophotogrammetry systems is challenging when targeting children's gait analysis due to the time required and the need to keep physical markers in place. For this reason, marker-less photoelectric systems appear to be a solution for accurate and fast gait analysis in youth. The aim of this study is to validate a photoelectric system and its configurations (LED filter setting) on healthy children, comparing the kinematic gait parameters with those obtained from a three-dimensional stereophotogrammetry system. Twenty-seven healthy children were enrolled. Three LED filter settings for the OptoGait were compared to the BTS P6000. The analysis included the non-parametric 80% limits of agreement and the intraclass correlation coefficient (ICC). Additionally, normalised limits of agreement and bias (NLoAs and Nbias) were compared to the clinical experience of physical therapists (i.e., assuming an error lower than 5% is acceptable). ICCs showed excellent consistency for most of the parameters and filter settings; NLoAs varied between 1.39% and 12.62%. An inverse association between the number of LEDs for filter setting and the bias values was also observed. Observations confirm the validity of the OptoGait system for the evaluation of spatiotemporal gait parameters in children.

Indexed as

GaitGait AnalysisBiomechanical PhenomenaChildHumansReproducibility of ResultsSpatio-Temporal AnalysisWalkingchildgait analysiskinematicsphotoelectric systemrehabilitationwalking

Identifiers

PMID37447908
PMCPMC10346440

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked