ArticleSensors (Basel, Switzerland)2023
Validity and Reliability of a Load Cell Sensor-Based Device for Assessment of the Isometric Mid-Thigh Pull Test.
Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed.
- Agreement and Reliability of the G-Force System: Force Plate and Load Cell for the Isometric Mid-Thigh Pull in Physically Active Adults: A Repeated-Measures Method-Comparison Study.Sensors (Basel, Switzerland) · 2026Article
- Influence of implant macrodesign and insertion load during implant placement on primary stability in artificial bone.International journal of implant dentistry · 2025Article
- Reliability and Accuracy of Linear Position Transducers During the Bench Press and Back Squat: Implications for Velocity-Based Training.Journal of functional morphology and kinesiology · 2025Article
- Are counter movement jump and isometric mid-thigh pull tests reliable, valid, and sensitive measurement instruments when performed after maximal cardiopulmonary exercise testing? A sex-based analysis in elite athletes.Frontiers in physiology · 2025Article
- Temperature field analysis and compensation improvement of load cell.Scientific reports · 2024Article
- Pre-Exercise Caffeine and Sodium Bicarbonate: Their Effects on Isometric Mid-Thigh Pull Performance in a Crossover, Double-Blind, Placebo-Controlled Study.Sports (Basel, Switzerland) · 2024Article
- Analysis of Return-to-Zero Error after the First Load of Load Cell.Sensors (Basel, Switzerland) · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In recent years, there has been an exponential increase in the number of devices developed to measure or estimate physical exercise. However, before these devices can be used in a practical and research environment, it is necessary to determine their validity and reliability. The purpose of this study is to test the validity and reliability of a load cell sensor-based device (LC) for measuring the peak force (PFr) and the rate of force development (RFD) during the isometric mid-thigh pull (IMTP) test, using a force plate (FP) as the gold standard. Forty-two undergraduate sport science students (male and female) participated in this study. In a single session, they performed three repetitions of the IMTP test, being tested simultaneously with an LC device and a Kistler force platform (FP). The PFr and RFD data were obtained from the force-time curve of the FP and compared with the LC data, provided automatically by the software of the device (Smart Traction device©). The mean difference between the results obtained by the LC device and the gold-standard equipment (FP) was not significantly different (
Indexed as
Identifiers
What OpenQuestion holds
Registered trials