Evidence map›Paper›PMID 37446900›Full record

ArticleMolecules (Basel, Switzerland)2023

An Amperometric Biosensor Based on a Bilayer of Electrodeposited Graphene Oxide and Co-Crosslinked Tyrosinase for L-Dopa Detection in Untreated Human Plasma.

Giuseppa Cembalo, Rosanna Ciriello, Carmen Tesoro, Antonio Guerrieri, Giuliana Bianco, Filomena Lelario, Maria Assunta Acquavia, Angela Di Capua

Open access · goldAbstract read
In one paragraph

Article in Molecules (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.3field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Review
  6. Molecules (Basel, Switzerland) · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Giuseppa CembaloDipartimento di Scienze, University of Basilicata, Via dell'Ateneo Lucano 10, 85100 Potenza, Italy.
Rosanna CirielloDipartimento di Scienze, University of Basilicata, Via dell'Ateneo Lucano 10, 85100 Potenza, Italy.
Carmen TesoroDipartimento di Scienze, University of Basilicata, Via dell'Ateneo Lucano 10, 85100 Potenza, Italy.
Antonio GuerrieriDipartimento di Scienze, University of Basilicata, Via dell'Ateneo Lucano 10, 85100 Potenza, Italy.ORCID 0000-0002-1662-5203
Giuliana BiancoDipartimento di Scienze, University of Basilicata, Via dell'Ateneo Lucano 10, 85100 Potenza, Italy.ORCID 0000-0001-9427-2274
Filomena LelarioDipartimento di Scienze, University of Basilicata, Via dell'Ateneo Lucano 10, 85100 Potenza, Italy.ORCID 0000-0002-6510-9395
Maria Assunta AcquaviaDipartimento di Scienze, University of Basilicata, Via dell'Ateneo Lucano 10, 85100 Potenza, Italy.ORCID 0000-0001-6103-8860
Angela Di CapuaDipartimento di Scienze, University of Basilicata, Via dell'Ateneo Lucano 10, 85100 Potenza, Italy.ORCID 0000-0001-6960-0715
University of Basilicata · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

L-Dopa, a bioactive compound naturally occurring in some Leguminosae plants, is the most effective symptomatic drug treatment for Parkinson's disease. During disease progression, fluctuations in L-DOPA plasma levels occur, causing motor complications. Sensing devices capable of rapidly monitoring drug levels would allow adjusting L-Dopa dosing, improving therapeutic outcomes. A novel amperometric biosensor for L-Dopa detection is described, based on tyrosinase co-crosslinked onto a graphene oxide layer produced through electrodeposition. Careful optimization of the enzyme immobilization procedure permitted to improve the long-term stability while substantially shortening and simplifying the biosensor fabrication. The effectiveness of the immobilization protocol combined with the enhanced performances of electrodeposited graphene oxide allowed to achieve high sensitivity, wide linear range, and a detection limit of 0.84 μM, suitable for L-Dopa detection within its therapeutic window. Interference from endogenous compounds, tested at concentrations levels typically found in drug-treated patients, was not significant. Ascorbic acid exhibited a tyrosinase inhibitory behavior and was therefore rejected from the enzymatic layer by casting an outer Nafion membrane. The proposed device was applied for L-Dopa detection in human plasma, showing good recoveries.

Indexed as

Biosensing TechniquesGraphiteElectrochemical TechniquesHumansLevodopaMonophenol Monooxygenasegraphene oxideGraphiteLevodopaMonophenol Monooxygenaseco-crosslinkingelectrochemical detectionelectrodepositiongraphene oxidehuman plasmaL-Dopatyrosinase

Identifiers

PMID37446900
PMCPMC10343914
OpenAlexW4383551216

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.