Evidence map›Paper›PMID 37445875›Full record

ReviewInternational journal of molecular sciences2023

Contact Dermatitis to Diabetes Medical Devices.

Mikołaj Cichoń, Magdalena Trzeciak, Małgorzata Sokołowska-Wojdyło, Roman J Nowicki

Open access · goldAbstract readReview
In one paragraph

Review in International journal of molecular sciences, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
7.1field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 25 citations in OpenAlex.

  1. Design, Construction, and Application of Implantable Fiber Biosensors.Advanced materials (Deerfield Beach, Fla.) · 2026
    Review
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Review
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Mikołaj CichońDepartment of Dermatology, Venereology and Allergology, Medical University of Gdansk, 80-214 Gdansk, Poland.ORCID 0000-0001-6476-0824
Magdalena TrzeciakDepartment of Dermatology, Venereology and Allergology, Medical University of Gdansk, 80-214 Gdansk, Poland.ORCID 0000-0002-8206-8441
Małgorzata Sokołowska-WojdyłoDepartment of Dermatology, Venereology and Allergology, Medical University of Gdansk, 80-214 Gdansk, Poland.ORCID 0000-0002-7626-3689
Roman J NowickiDepartment of Dermatology, Venereology and Allergology, Medical University of Gdansk, 80-214 Gdansk, Poland.ORCID 0000-0003-4768-1387
Gdańsk Medical University · PL

Funding

Polish Ministry of Science and Higher Education 02-0066/07/253
6 · The paper itself

Abstract

Skin adverse reactions to diabetes medical devices have been reported frequently over recent years. Adhesives attaching glucose sensors and continuous insulin infusion sets to the skin are proven to cause both allergic contact dermatitis and irritant contact dermatitis in patients with diabetes mellitus. Several allergens contained in adhesives and/or parts of medical devices are documented to cause allergic contact dermatitis, with acrylate chemicals being the most common culprit-especially isobornyl acrylate (IBOA), but also 2,2'-methylenebis(6-tert-butyl-4-methylphenol) monoacrylate or cyanoacrylates. Epoxy resin, colophonium and nickel were also identified as causative allergens. However, repetitive occlusion, maceration of the skin and resulting disruption of the skin barrier seem to have an impact on the development of skin lesions as well. The purpose of this study is to highlight the burden of contact dermatitis triggered by diabetes medical devices and to show possible mechanisms responsible for the development of contact dermatitis in a group of diabetic patients.

Indexed as

Dermatitis, Allergic ContactDiabetes MellitusAcrylatesAdhesivesAllergensBlood Glucose Self-MonitoringHumansInsulin Infusion SystemsAcrylatesAdhesivesAllergens2,2′-methylenebis(6-tert-butyl-4-methylphenol) monoacrylateallergic contact dermatitisdiabetes medical devicesglucose sensorsIBOAinsulin pumpsirritant contact dermatitisisobornyl acrylateMBPA