Evidence map›Paper›PMID 37445228›Full record

ArticleJournal of clinical medicine2023

Investigation of the Influence of Roughness and Dental Implant Design on Primary Stability via Analysis of Insertion Torque and Implant Stability Quotient: An In Vitro Study.

Marta Romero, Mariano Herrero-Climent, Blanca Ríos-Carrasco, Aritza Brizuela, Manuel María Romero, Javier Gil

Open access · goldAbstract read
In one paragraph

Article in Journal of clinical medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
4.6field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 18 citations in OpenAlex.

  1. Approach of Dental Implants Through the Transfer-Matrix Method.Bioengineering (Basel, Switzerland) · 2026
    Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Marta RomeroDepartment of Periodontology, School of Dentistry, Universidad de Seville, C/Avicena S/N, 41009 Seville, Spain.
Mariano Herrero-ClimentDepartment of Periodontology, School of Dentistry, Universidad de Seville, C/Avicena S/N, 41009 Seville, Spain.ORCID 0000-0003-3284-1528
Blanca Ríos-CarrascoDepartment of Periodontology, School of Dentistry, Universidad de Seville, C/Avicena S/N, 41009 Seville, Spain.ORCID 0000-0002-2832-5902
Aritza BrizuelaDensia Reserach Group, Facultad de Ciencias de la Salud, Universidad Europea Miguel de Cervantes, C/del Padre Julio Chevalier 2, 47012 Valladolid, Spain.ORCID 0000-0001-6421-3863
Manuel María RomeroDepartment of Periodontology, School of Dentistry, Universidad de Seville, C/Avicena S/N, 41009 Seville, Spain.
Javier GilBioengineering Institute of Technology, Faculty of Medicine and Health Sciences, Universidad International de Cataluña, C/Josep Trueta s/n, Sant Cugat del Vallés, 08195 Barcelona, Spain.ORCID 0000-0002-6824-1412
Universidad de Sevilla · ESUniversidad Europea Miguel de Cervantes · ESUniversitat Internacional de Catalunya · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In the placement of dental implants, the primary fixation between the dental implant and the bone is of great importance and corresponds to compressive mechanical fixation that aims to prevent micromovement of the implant. The aim of this research was to determine the role of roughness and the type of dental implant (tissue-level or bone-level) in implant stability, measured using resonance frequency analysis (RFA) and insertion torque (IT). We analyzed 234 titanium dental implants, placed in fresh calf ribs, at the half-tissue level and half-bone level. The implant surface was subjected to grit-blasting treatments with alumina particles of 120, 300, and 600 μm at a projection pressure of 2.5 bar, resulting in three types of roughness. Roughness was determined via optical interferometry. The wettability of the surfaces was also determined. Implant stability was measured using a high-precision torquemeter to obtain IT, and RFA was used to determine the implant stability quotient (ISQ). The results show that rough surfaces with Sa values of 0.5 to 4 μm do not affect the primary stability. However, the type of implant is important; bone-level implants obtained the highest primary stability values. A good correlation between the primary stability values obtained via IT and ISQ was demonstrated. New in vivo studies are necessary to know whether these results can be maintained in the long term.

Indexed as

dental implantimplant stability quotientinsertion torqueprimary stabilitytitanium

Identifiers

PMID37445228
PMCPMC10342708
OpenAlexW4381795595

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked