Evidence map›Paper›PMID 37445014›Full record

ReviewMaterials (Basel, Switzerland)2023

Polymeric Coatings for Magnesium Alloys for Biodegradable Implant Application: A Review.

G Keerthiga, M J N V Prasad, Dandapani Vijayshankar, R K Singh Raman

Abstract readReview
In one paragraph

Review in Materials (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Review
  5. [Structural design and evaluation of bone remodeling effect of fracture internal fixation implants with time-varying stiffness].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2024
    Article
  6. Review
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

G KeerthigaIITB-Monash Research Academy, Mumbai 400076, Maharashtra, India.ORCID 0000-0002-1172-486X
M J N V PrasadMicrostructural Engineering and Mechanical Performance Laboratory, Department of Metallurgical Engineering and Materials Science, Indian Institute of Technology Bombay, Mumbai 400076, Maharashtra, India.ORCID 0000-0003-4651-6419
Dandapani VijayshankarElectrochemistry at Interface Lab, Department of Metallurgical Engineering and Materials Science, Indian Institute of Technology Bombay, Mumbai 400076, Maharashtra, India.ORCID 0000-0003-2767-7962
R K Singh RamanDepartment of Chemical and Biological Engineering, Monash University, Clayton, VIC 3800, Australia.ORCID 0000-0002-3157-634X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Magnesium (Mg) alloys are a very attractive material of construction for biodegradable temporary implants. However, Mg alloys suffer unacceptably rapid corrosion rates in aqueous environments, including physiological fluid, that may cause premature mechanical failure of the implant. This necessitates a biodegradable surface barrier coating that should delay the corrosion of the implant until the fractured/damaged bone has healed. This review takes a brief account of the merits and demerits of various existing coating methodologies for the mitigation of Mg alloy corrosion. Since among the different coating approaches investigated, no single coating recipe seems to address the degradation control and functionality entirely, this review argues the need for polymer-based and biodegradable composite coatings.

Indexed as

biodegradable implantsmagnesium alloyspolymeric coatings