Evidence map›Paper›PMID 37444822›Full record

ArticleMaterials (Basel, Switzerland)2023

Effect of Fluoride Coatings on the Corrosion Behavior of Mg-Zn-Ca-Mn Alloys for Medical Application.

Tiberiu Bita, Aurora Antoniac, Ion Ciuca, Marian Miculescu, Cosmin Mihai Cotrut, Gheorghe Paltanea, Horatiu Dura, Iuliana Corneschi, Iulian Antoniac, Ioana Dana Carstoc and 1 more

Open access · goldAbstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.0field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 10 citations in OpenAlex.

  1. Review
  2. Article
  3. Review
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 4 institutions in 1 country.

Tiberiu BitaFaculty of Material Science and Engineering, University Politehnica of Bucharest, 313 Splaiul Independentei, District 6, 060042 Bucharest, Romania.
Aurora AntoniacFaculty of Material Science and Engineering, University Politehnica of Bucharest, 313 Splaiul Independentei, District 6, 060042 Bucharest, Romania.
Ion CiucaFaculty of Material Science and Engineering, University Politehnica of Bucharest, 313 Splaiul Independentei, District 6, 060042 Bucharest, Romania.
Marian MiculescuFaculty of Material Science and Engineering, University Politehnica of Bucharest, 313 Splaiul Independentei, District 6, 060042 Bucharest, Romania.ORCID 0000-0002-2723-6713
Cosmin Mihai CotrutFaculty of Material Science and Engineering, University Politehnica of Bucharest, 313 Splaiul Independentei, District 6, 060042 Bucharest, Romania.ORCID 0000-0002-8991-7485
Gheorghe PaltaneaFaculty of Electrical Engineering, University Politehnica of Bucharest, 313 Splaiul Independentei, District 6, 060042 Bucharest, Romania.ORCID 0000-0003-3251-7146
Horatiu DuraFaculty of Medicine, Lucian Blaga University of Sibiu, 2A Lucian Blaga Street, 550169 Sibiu, Romania.
Iuliana CorneschiRomfire Protect Solution S.R.L., 39 Drumul Taberei, District 6, 061359 Bucharest, Romania.
Iulian AntoniacFaculty of Material Science and Engineering, University Politehnica of Bucharest, 313 Splaiul Independentei, District 6, 060042 Bucharest, Romania.ORCID 0000-0003-0112-3494
Ioana Dana CarstocFaculty of Medicine, Lucian Blaga University of Sibiu, 2A Lucian Blaga Street, 550169 Sibiu, Romania.
Alin Danut BodogFaculty of Medicine and Pharmacy, University of Oradea, 10 P-ta 1 December Street, 410073 Oradea, Romania.ORCID 0000-0002-1988-6994
Universitatea Națională de Știință și Tehnologie Politehnica București · ROLucian Blaga University of Sibiu · ROAcademia Oamenilor de Știință din România · ROUniversity of Oradea · RO

Funding

Unitatea Executiva Pentru Finantarea Invatamantului Superior a Cercetarii Dezvoltarii si Inovarii PN-III-P4-ID-PCE-2020-2591
6 · The paper itself

Abstract

The most critical shortcoming of magnesium alloys from the point of view of medical devices is the high corrosion rate, which is not well-correlated with clinical needs. It is well- known that rapid degradation occurs when an implant made of Mg-based alloys is placed inside the human body. Consequently, the implant loses its mechanical properties and failure can occur even if it is not completely degraded. The corrosion products that appear after Mg-based alloy degradation, such as H

Indexed as

corrosionfluoride conversionMg–Zn–Ca–Mn magnesium alloysurface

Identifiers

PMID37444822
PMCPMC10342772
OpenAlexW4381686101

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.