Evidence map›Paper›PMID 37444403›Full record

ArticleCancers2023

Ultrasound Imaging with Flexible Array Transducer for Pancreatic Cancer Radiation Therapy.

Xinyue Huang, Hamed Hooshangnejad, Debarghya China, Ziwei Feng, Junghoon Lee, Muyinatu A Lediju Bell, Kai Ding

Open access · goldAbstract read
In one paragraph

Article in Cancers, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
3.9field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 11 citations in OpenAlex.

  1. Review
  2. Article
  3. UltraFlex: Iterative Model-Based Ultrasonic Flexible-Array Shape Calibration.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2025
    Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Xinyue HuangDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21287, USA.ORCID 0000-0001-5202-3368
Hamed HooshangnejadDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21287, USA.
Debarghya ChinaDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21287, USA.ORCID 0000-0001-9053-8119
Ziwei FengDepartment of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, MD 21287, USA.ORCID 0000-0002-5003-4220
Junghoon LeeDepartment of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, MD 21287, USA.
Muyinatu A Lediju BellDepartment of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, MD 21287, USA.ORCID 0000-0002-8394-4482
Kai DingDepartment of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, MD 21287, USA.ORCID 0000-0002-8202-0173
Johns Hopkins University · US

Funding

National Institute of Health R37CA229417
6 · The paper itself

Abstract

Pancreatic cancer with less than 10% 3-year survival rate is one of deadliest cancer types and greatly benefits from enhanced radiotherapy. Organ motion monitoring helps spare the normal tissue from high radiation and, in turn, enables the dose escalation to the target that has been shown to improve the effectiveness of RT by doubling and tripling post-RT survival rate. The flexible array transducer is a novel and promising solution to address the limitation of conventional US probes. We proposed a novel shape estimation for flexible array transducer using two sequential algorithms: (i) an optical tracking-based system that uses the optical markers coordinates attached to the probe at specific positions to estimate the array shape in real-time and (ii) a fully automatic shape optimization algorithm that automatically searches for the optimal array shape that results in the highest quality reconstructed image. We conducted phantom and in vivo experiments to evaluate the estimated array shapes and the accuracy of reconstructed US images. The proposed method reconstructed US images with low full-width-at-half-maximum (FWHM) of the point scatters, correct aspect ratio of the cyst, and high-matching score with the ground truth. Our results demonstrated that the proposed methods reconstruct high-quality ultrasound images with significantly less defocusing and distortion compared with those without any correction. Specifically, the automatic optimization method reduced the array shape estimation error to less than half-wavelength of transmitted wave, resulting in a high-quality reconstructed image.

Indexed as

abdominal motion monitoringflexible array transducergastrointestinal malignanciespancreatic cancerultrasound imaging

Identifiers

PMID37444403
PMCPMC10340354
OpenAlexW4381805885

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.