Evidence map›Paper›PMID 37443461›Full record

ArticleAsian spine journal2023

The Feasibility of Multiple Fixation Points in C2.

Quyen Nguyen Ngoc, K Daniel Riew, So Min Lee, Sang-Min Park, Ho-Joong Kim, Bong-Soon Chang, Sang-Hun Lee, Jae Chul Lee, Jin S Yeom

Open access · diamondAbstract read
In one paragraph

Article in Asian spine journal, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.3field-weighted citation impact, top 40% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 6 institutions in 3 countries.

Quyen Nguyen NgocSpine Surgery Unit, Polyclinic and Premier Healthcare Center, 108 Military Central Hospital, Hanoi, Socialist Republic of Vietnam.
K Daniel RiewDepartment of Orthopedic Surgery, Columbia University, New York, NY, USA.
So Min LeeSpine Center and Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam, Korea.
Sang-Min ParkSpine Center and Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam, Korea.
Ho-Joong KimSpine Center and Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam, Korea.
Bong-Soon ChangDepartment of Orthopaedic Surgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea.
Sang-Hun LeeDepartment of Orthopaedic Surgery, Johns Hopkins University, School of Medicine, Baltimore, MD, USA.
Jae Chul LeeDepartment of Orthopaedic Surgery, Soonchunhyang University Seoul Hospital, Seoul, Korea.
Jin S YeomSpine Center and Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam, Korea.
Seoul National University Bundang Hospital · KR108 Military Central Hospital · VNJohns Hopkins University · USNeurological Surgery · USSeoul National University Hospital · KRSoonchunhyang University Hospital Seoul · KR

Funding

Seoul National University Bundang Hospital 02-2014-060
6 · The paper itself

Abstract

STUDY

designAnalysis using three-dimensional simulation software for spinal screw placement and computed tomographic scan images. PURPOSE: To assess the feasibility of achieving multiple (three or four) screw fixation points in C2 vertebra by using a combination of pedicle and laminar screws. OVERVIEW OF LITERATURE: Secure C2 fixation using multiple screws is required or beneficial in some unique cases. However, to the best of our knowledge, there have been no reports analyzing the feasibility of multiple screw fixation in C2.

methodsWe used 1.0-mm interval computed tomographic scan images of 100 patients (50 men and 50 women) and screw trajectory simulation software. The diameter of all screws was set at 3.5 mm, considering its common usage in real surgery. The anatomical feasibility of placing both pedicle and laminar screws on the same side was evaluated. For all feasible sides, the three-dimensional distance between the screw entry points was measured.

resultsIn 85% of cases, both pedicle and laminar screws could be placed on both sides, allowing for the insertion of 4 screws. In 11% of cases, 2 screws could be placed on one side, while only 1 screw was feasible on the other side, resulting in the placement of 3 screws. In all 181 sides where both types of screws could be inserted, the distance between their entry points exceeded 16.1 mm, which was sufficient to prevent the collision between the screw heads.

conclusionsC2 vertebra can accommodate three (11%) or four (85%) screws in 96% of cases.

Indexed as

C2Laminar screwMultiple screw fixationPedicle screw

Identifiers

PMID37443461
PMCPMC10622824
OpenAlexW4384277258

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.