Evidence map›Paper›PMID 37443027›Full record

ArticleBMC oral health2023

Evaluation of enamel roughness after orthodontic debonding and clean-up procedures using zirconia, tungsten carbide, and white stone burs: an in vitro study.

Ahmed A Thawaba, Nehal F Albelasy, Amira M Elsherbini, Ahmad M Hafez

Registry-linked trialOpen access · goldAbstract read
In one paragraph

Article in BMC oral health, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT07304310 (Clinical Evaluation of Two Minimally Invasive Protocols for Orthodontic Clean-Up), which is not on this map. Cited by 17 papers.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed
4.6field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT07304310 completednot on this mapstarted 2025, after this paper: background citation

Clinical Evaluation of Two Minimally Invasive Protocols for Orthodontic Clean-Up: A Case-Control Study

TypeobservationalSponsorIRCCS San RaffaeleRan2025 to 2025Enrolled142ConditionsOrthodontic Appliance, Debonding, Case-control StudyArmsTwo-step ultrasonic protocol, One-step clean-up protocol
3 · Its place in the literature

Who cites it

17 citing papers in PubMed, 22 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Article
  9. Effect of the COFrontiers in dental medicine · 2026
    Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Ahmed A ThawabaDepartment of Orthodontic, Faculty of Dentistry, Mansoura University, Mansoura, Egypt. mr.thawaba2021@gmail.com.ORCID 0000-0002-9380-1477
Nehal F AlbelasyDepartment of Orthodontic, Faculty of Dentistry, Mansoura University, Mansoura, Egypt.
Amira M ElsherbiniDepartment of Oral Biology, Faculty of Dentistry, Mansoura University, Mansoura, Egypt.
Ahmad M HafezDepartment of Orthodontic, Faculty of Dentistry, Mansoura University, Mansoura, Egypt.
Mansoura University · EG

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe main goal of orthodontic debonding is to restore the enamel surface as closely as possible to its pretreatment condition without iatrogenic damage. This study aimed to compare the effects of different adhesive removal burs; zirconia burs, tungsten carbide burs, and white stone burs on enamel surface roughness. MATERIALS AND

methodsTotal sample of 72 extracted premolars was randomly divided into three equal groups (n = 24) depending on the method of adhesive removal: zirconia burs (ZB); tungsten carbide burs (TC); and white stones (WS). The metal brackets were bonded using Transbond XT orthodontic adhesive (3 M Unitek, Monrovia, CA, USA) and debonded after 24 h using a debonding plier, then the ARI was assessed. The adhesive remnants were removed using the different burs and Final polishing was performed using Sof-lex discs and spirals. Thirteen samples from each group were evaluated using a Mitutoyo SJ-210 profilometer to determine average surface roughness (Ra) and three samples from each group were examined under Scanning Electron Microscopy (SEM) to determine EDI score. The evaluations were performed at three time points; before bonding (T0), after adhesive removal (T1) and after polishing (T2) and the time consumed for adhesive removal by burs was recorded in seconds. The data were analyzed statistically by ANOVA, Tukey's test and Kruskal-Wallis H-test.

resultsKruskal-Wallis H-test showed no statistically significant difference of ARI in all studied groups (p = 0.845) and two-way mixed ANOVA revealed that all burs significantly increased surface roughness at T1 compared to T0 (p < 0.001) in all groups with the lowest Ra values were observed in the ZB group, followed by the TC group, and WS group. The fastest procedure was performed with WS, followed by ZB, then TC bur (p < 0.001). After polishing (T2), Ra values showed no significant difference in ZB group (P = 0.428) and TC group (P = 1.000) as compared to T0, while it was significant in WS group (p < 0.001).

conclusionzirconia bur was comparable to tungsten carbide bur and can be considered as alternative to white stone which caused severe enamel damage. The polishing step created smoother surface regardless of the bur used for resin removal.

Indexed as

Dental CementsOrthodontic BracketsDental DebondingDental EnamelHumansSurface PropertiesTungsten CompoundsZirconiumDental Cementstungsten carbideTungsten CompoundsZirconiumzirconium oxideDental debondingDental enamelDental PolishingOrthodontic bracketsSurface Properties

Identifiers

PMID37443027
PMCPMC10339551
OpenAlexW4384131502

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.