Evidence map›Paper›PMID 37440093›Full record

ArticleIrish journal of medical science2024

Accuracy of the Apple Watch in measuring oxygen saturation: comparison with pulse oximetry and ABG.

Banu Arslan, Kemal Sener, Ramazan Guven, Mucahit Kapci, Semih Korkut, Mehmet N Sutasir, Mustafa A Tekindal

Registry-linked trialAbstract read
PubMed Publisher
In one paragraph

Article in Irish journal of medical science, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT07311135 (Accuracy of Wrist-worn Pulse Oximeter SpO2 Measurements in Patients Diagnosed With Pulmonary Hypertension), which is not on this map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT07311135 recruitingnot on this mapstarted 2025, after this paper: background citation

Accuracy of Wrist-worn Pulse Oximeter SpO2 Measurements in Patients Diagnosed With Pulmonary Hypertension

TypeobservationalSponsorGolden Jubilee National HospitalRan2025 to 2026Enrolled20ConditionsPulmonary Hypertension
3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Observational
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Banu ArslanDepartment of Emergency Medicine, Basaksehir Cam and Sakura City Hospital, Istanbul, Turkey. dr.banuarslan@gmail.com.ORCID http://orcid.org/0000-0003-0982-5351
Kemal SenerDepartment of Emergency Medicine, Basaksehir Cam and Sakura City Hospital, Istanbul, Turkey.
Ramazan GuvenDepartment of Emergency Medicine, Basaksehir Cam and Sakura City Hospital, Istanbul, Turkey.
Mucahit KapciDepartment of Emergency Medicine, Basaksehir Cam and Sakura City Hospital, Istanbul, Turkey.
Semih KorkutDepartment of Emergency Medicine, Basaksehir Cam and Sakura City Hospital, Istanbul, Turkey.
Mehmet N SutasirDepartment of Emergency Medicine, Basaksehir Cam and Sakura City Hospital, Istanbul, Turkey.
Mustafa A TekindalDepartment of Biostatistics, İzmir Katip Celebi University Faculty of Medicine, İzmir, Turkey.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSmartwatches have gained tremendous attention in recent years and have become widely accepted by patients, despite not being intended for medical diagnosis.

objectiveThis study aimed to determine the accuracy of Apple Watch oxygen saturation measurement in patients with acute exacerbation of COPD by comparing it with medical-grade pulse oximetry and ABG.

methodThis single-center, prospective, cross-sectional study involved 167 patients. Patients presenting with cardiac arrest, life-threatening symptoms, severe hypoxia, or obvious jaundice were excluded. Additionally, patients whose SpO

resultsA strong correlation between the Apple Watch 6 and medical-grade pulse oximetry (r = 0.89, ICC = 0.940) was noted. The Bland-Altman analysis revealed a mean error of 0.458% between the Apple Watch 6 and ABG (SD: 2.78, level of agreement: - 5.912 to 4.996). The mean error between pulse oximetry and ABG (SD: 5.086, level of agreement; - 10.983 to 8.953) was 1.015%. There was a correlation between respiratory rate and the number of attempts to measure SpO

conclusionApple Watch 6 is an accurate and reliable method for measuring SpO

Indexed as

Oxygen SaturationPulmonary Disease, Chronic ObstructiveCross-Sectional StudiesHumansOximetryOxygenProspective StudiesOxygenApple WatchCOPD exacerbationPulse oximeterSmartwatchWearables

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.