Evidence map›Paper›PMID 37439804›Full record

ArticleHerz2024

Accuracy of VO

Theresa Reiter, Julia Kerzner, Georg Fette, Stefan Frantz, Wolfram Voelker, Georg Ertl, Wolfgang Bauer, Caroline Morbach, Stefan Störk, Gülmisal Güder

Abstract read
In one paragraph

Article in Herz, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Theresa ReiterDepartment of Internal Medicine I, Cardiology Division, University Hospital Würzburg, Oberdürrbacherstr. 6, 97080, Würzburg, Germany.
Julia KerznerDepartment of Internal Medicine I, Cardiology Division, University Hospital Würzburg, Oberdürrbacherstr. 6, 97080, Würzburg, Germany.
Georg FetteDepartment of Clinical Research & Epidemiology, Comprehensive Heart Failure Center, University Hospital Würzburg, Am Schwarzen Berg 26, 97078, Würzburg, Germany.
Stefan FrantzDepartment of Internal Medicine I, Cardiology Division, University Hospital Würzburg, Oberdürrbacherstr. 6, 97080, Würzburg, Germany.
Wolfram VoelkerDepartment of Internal Medicine I, Cardiology Division, University Hospital Würzburg, Oberdürrbacherstr. 6, 97080, Würzburg, Germany.
Georg ErtlDepartment of Clinical Research & Epidemiology, Comprehensive Heart Failure Center, University Hospital Würzburg, Am Schwarzen Berg 26, 97078, Würzburg, Germany.
Wolfgang BauerDepartment of Internal Medicine I, Cardiology Division, University Hospital Würzburg, Oberdürrbacherstr. 6, 97080, Würzburg, Germany.
Caroline MorbachDepartment of Internal Medicine I, Cardiology Division, University Hospital Würzburg, Oberdürrbacherstr. 6, 97080, Würzburg, Germany.
Stefan StörkDepartment of Internal Medicine I, Cardiology Division, University Hospital Würzburg, Oberdürrbacherstr. 6, 97080, Würzburg, Germany.
Gülmisal GüderDepartment of Internal Medicine I, Cardiology Division, University Hospital Würzburg, Oberdürrbacherstr. 6, 97080, Würzburg, Germany. gueder_g@ukw.de.ORCID http://orcid.org/0000-0002-5598-5359

Funding

Bundesministerium für Bildung und Forschung 01EO1504Julius-Maximilians-Universität Würzburg Open Access Publication Fund
6 · The paper itself

Abstract

backgroundInvasive cardiac output (CO) is measured with the thermodilution (TD) or the indirect Fick method (iFM) in right heart catheterization (RHC). The iFM estimates CO using approximation formulas for oxygen consumption ([Formula: see text]O

methodsThis retrospective study included 188 patients aged 63 ± 14 years (30% women) receiving both CMR and RHC. The CO was measured with TD or with the iFM using the formulas by Krakau, LaFarge, Dehmer, and Bergstra for [Formula: see text]O2 estimation (iFM-K/-L/-D/-B). Percentage errors were calculated as twice the standard deviation of the difference between two CO methods divided by their means; a cut-off of < 30% was regarded as acceptable. The iFM and TD-derived CO ratio was built, and deviations > 20% were counted. Logistic regression analyses were performed to identify determinants of a deviation of > 20%.

resultsThe TD-derived CO (5.5 ± 1.7 L/min) was significantly different from all iFM (K: 4.8 ± 1.6, L: 4.3 ± 1.6; D: 4.8 ± 1.5 L/min; B: 5.4 ± 1.8 L/min all p < 0.05). The iFM-K-CO differed from all methods (p < 0.001) except iFM‑D (p = 0.19). Percentage errors between TD-CO and iFM-K/-L/-D/-B were all beyond the acceptance limit (44/45/44/43%), while percentage errors between iFM‑K and other iFM were all < 16%. None of the parameters measured in CMR was predictive of a discrepancy of > 20% between both methods.

conclusionThe Krakau formula was comparable to other iFM in estimating CO levels, but none showed satisfactory agreement with the TD method. Improved derivation cohorts for [Formula: see text]O

Indexed as

Cardiac CatheterizationThermodilutionCardiac OutputFemaleHumansMaleOxygen ConsumptionRetrospective StudiesCardiac outputIndirect Fick methodO2 approximationThermodilution

Identifiers

PMID37439804
PMCPMC10830659

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.