Evidence map›Paper›PMID 37437005›Full record

ArticlePLOS digital health2023

Investigating the accuracy of blood oxygen saturation measurements in common consumer smartwatches.

Yihang Jiang, Connor Spies, Justin Magin, Satasuk Joy Bhosai, Laurie Snyder, Jessilyn Dunn

Registry-linked trialOpen access · goldAbstract read
In one paragraph

Article in PLOS digital health, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT07512687 (Impact of Ambulatory Oxygen Delivery on Real-world Activity and Quality-of-life in Patients With Interstitial Lung Disease), which is not on this map. Cited by 19 papers.

0numbers the graph read from it
0cells of the map it votes in
19citing papers in PubMed
3.3field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT07512687 narecruitingnot on this mapstarted 2026, after this paper: background citation

Impact of Ambulatory Oxygen Delivery on Real-world Activity and Quality-of-life in Patients With Interstitial Lung Disease (ILD) and Chronic Obstructive Pulmonary Disease (COPD)

TypeinterventionalSponsorState University of New York at BuffaloRan2026 to 2027Enrolled24ConditionsInterstitial Lung Disease, Chronic Obstructive Pulmonary Disease, HypoxemiaArmsPortable Oxygen Concentrator, Portable compressed oxygen D-tanks, No ambulatory oxygen therapy
3 · Its place in the literature

Who cites it

19 citing papers in PubMed, 30 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. CMOS-Compatible ZrOACS applied materials & interfaces · 2026
    Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Review
  11. Review
  12. Review
  13. Article
  14. Article
  15. Review
  16. Review
  17. Review
  18. Article
  19. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Yihang JiangDepartment of Biomedical Engineering, Duke University, Durham, North Carolina, United States of America.ORCID https://orcid.org/0000-0003-2062-7946
Connor SpiesDepartment of Medicine, Duke University, Durham, North Carolina, United States of America.
Justin MaginDepartment of Medicine, Duke University, Durham, North Carolina, United States of America.ORCID https://orcid.org/0000-0002-8663-5044
Satasuk Joy BhosaiDepartment of Medicine, Duke University, Durham, North Carolina, United States of America.
Laurie SnyderDepartment of Medicine, Duke University, Durham, North Carolina, United States of America.
Jessilyn DunnDepartment of Biomedical Engineering, Duke University, Durham, North Carolina, United States of America.ORCID https://orcid.org/0000-0002-3241-8183
Duke University · USUniversity of North Carolina at Chapel Hill · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Blood oxygen saturation (SpO2) is an important measurement for monitoring patients with acute and chronic conditions that are associated with low blood oxygen levels. While smartwatches may provide a new method for continuous and unobtrusive SpO2 monitoring, it is necessary to understand their accuracy and limitations to ensure that they are used in a fit-for-purpose manner. To determine whether the accuracy of and ability to take SpO2 measurements from consumer smartwatches is different by device type and/or by skin tone, our study recruited patients aged 18-85 years old, with and without chronic pulmonary disease, who were able to provide informed consent. The mean absolute error (MAE), mean directional error (MDE) and root mean squared error (RMSE) were used to evaluate the accuracy of the smartwatches as compared to a clinical grade pulse oximeter. The percent of data unobtainable due to inability of the smartwatch to record SpO2 (missingness) was used to evaluate the measurability of SpO2 from the smartwatches. Skin tones were quantified based on the Fitzpatrick (FP) scale and Individual Typology Angle (ITA), a continuous measure of skin tone. A total of 49 individuals (18 female) were enrolled and completed the study. Using a clinical-grade pulse oximeter as the reference standard, there were statistically significant differences in accuracy between devices, with Apple Watch Series 7 having measurements closest to the reference standard (MAE = 2.2%, MDE = -0.4%, RMSE = 2.9%) and the Garmin Venu 2s having measurements farthest from the reference standard (MAE = 5.8%, MDE = 5.5%, RMSE = 6.7%). There were also significant differences in measurability across devices, with the highest data presence from the Apple Watch Series 7 (88.9% of attempted measurements were successful) and the highest data missingness from the Withings ScanWatch (only 69.5% of attempted measurements were successful). The MAE, RMSE and missingness did not vary significantly across FP skin tone groups, however, there may be a relationship between FP skin tone and MDE (intercept = 0.04, beta coefficient = 0.47, p = 0.04). No statistically significant difference was found between skin tone as measured by ITA and MAE, MDE, RMSE or missingness.

Identifiers

PMID37437005
PMCPMC10337940
OpenAlexW4384025158

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.