Evidence map›Paper›PMID 37436599›Full record

Observational studyJournal of clinical monitoring and computing2023

Accuracy of non-invasive sensors measuring core body temperature in cardiac surgery ICU patients - results from a monocentric prospective observational study.

Georg Engelbart, Sebastian Brandt, Tobias Scheeren, Alexander Tzabazis, Oliver Kimberger, Patrick Kellner

Abstract readObservational Study
In one paragraph

Observational study in Journal of clinical monitoring and computing, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Georg Engelbart *Department of Anaesthesiology and Intensive Care Medicine, University Hospital Schleswig-Holstein, Ratzeburger Allee 160, D-23538, Lübeck, Germany.
Sebastian Brandt *Department of Anaesthesiology and Intensive Care Medicine, University Hospital Schleswig-Holstein, Ratzeburger Allee 160, D-23538, Lübeck, Germany.
Tobias ScheerenDepartment of Anaesthesiology and Intensive Care Medicine, University Hospital Schleswig-Holstein, Ratzeburger Allee 160, D-23538, Lübeck, Germany.
Alexander TzabazisDepartment of Anaesthesiology and Intensive Care Medicine, University Hospital Schleswig-Holstein, Ratzeburger Allee 160, D-23538, Lübeck, Germany.
Oliver KimbergerDepartment of Anaesthesia, Intensive Care Medicine and Pain Medicine, Medical University of Vienna, Vienna, Austria.
Patrick KellnerDepartment of Anaesthesiology and Intensive Care Medicine, University Hospital Schleswig-Holstein, Ratzeburger Allee 160, D-23538, Lübeck, Germany. patrick.kellner@uksh.de.ORCID 0000-0001-6274-3529

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTemperature monitoring in the perioperative setting often represents a compromise between accuracy, invasiveness of probe placement, and patient comfort. Transcutaneous sensors using the Zero-Heat-Flux (ZHF) and Double-Sensor (DS) technology have been developed and evaluated in a variety of clinical settings. The present study is the first to compare the performance of both sensors simultaneously with temperature measured by a Swan-Ganz catheter (PAC) in patients admitted to the intensive care unit (ICU) after cardiac surgery.

methodsIn this monocentric prospective observational study patients were postoperatively transferred to the ICU and both sensors were placed on the patients' foreheads. Core body temperature measured by intraoperatively placed PAC served as gold standard. Measurements were recorded at 5-minute intervals and up to 40 data sets per patient were recorded. Bland and Altman's method for repeated measurements was used to analyse agreement. Subgroup analyses for gender, body-mass-index, core temperature, airway status and different time intervals were performed. Lin's concordance correlation coefficient (LCCC) was calculated, as well as sensitivity and specificity for detecting hyperthermia (≥ 38 °C) and hypothermia (< 36 °C).

resultsOver a period of six month, we collected 1600 sets of DS, ZHF, and PAC measurements, from a total of 40 patients. Bland-Altman analysis revealed a mean bias of -0.82 ± 1.27 °C (average ± 95% Limits-of-Agreement (LoA)) and - 0.54 ± 1.14 °C for DS and ZHF, respectively. The LCCC was 0.5 (DS) and 0.63 (ZHF). Mean bias was significantly higher in hyperthermic and hypothermic patients. Sensitivity and specificity were 0.12 / 0.99 (DS) and 0.35 / 1.0 (ZHF) for hyperthermia and 0.95 / 0.72 (DS) and 1.0 / 0.85 (ZHF) for hypothermia.

conclusionCore temperature was generally underestimated by the non-invasive approaches. In our study, ZHF outperformed DS. In terms of agreement, results for both sensors were outside the range that is considered clinically acceptable. Nevertheless, both sensors might be adequate to detect postoperative hypothermia reliably when more invasive methods are not available or appropriate.

trial registrationGerman Register of Clinical Trials (DRKS-ID: DRKS00027003), retrospectively registered 10/28/2021.

Indexed as

Cardiac Surgical ProceduresHypothermiaBody TemperatureHumansIntensive Care UnitsProspective StudiesThermometersCore temperatureDouble-sensorNon-invasive monitoringPerioperative hypothermiaTemperature monitoringZero-heat-flux

Identifiers

PMID37436599
PMCPMC10651547

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.