Evidence map›Paper›PMID 37436475›Full record

ArticleNeuroradiology2023

Effect of magnet strength on fetal brain biometry - a single-center retrospective MRI-based cohort study.

Shai Shrot, Efrat Hadi, Yiftach Barash, Chen Hoffmann

Abstract read
PubMed Publisher
In one paragraph

Article in Neuroradiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.2field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 citations in OpenAlex.

  1. Article
  2. Automated Craniofacial Biometry with 3D T2w Fetal MRI.medRxiv : the preprint server for health sciences · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Shai ShrotSection of Neuroradiology, Division of Diagnostic Imaging, Sheba Medical Center, Tel Hashomer, 2 Sheba Rd, 52621, Ramat Gan, Israel. shai.shrot@sheba.health.gov.il.ORCID http://orcid.org/0000-0001-8954-3244
Efrat HadiDiagnostic Ultrasound Unit of the Institute of Obstetrical and Gynecological Imaging, Department of Obstetrics and Gynecology, Sheba Medical Center, 52621, Ramat Gan, Israel.
Yiftach BarashSection of Neuroradiology, Division of Diagnostic Imaging, Sheba Medical Center, Tel Hashomer, 2 Sheba Rd, 52621, Ramat Gan, Israel.
Chen HoffmannSection of Neuroradiology, Division of Diagnostic Imaging, Sheba Medical Center, Tel Hashomer, 2 Sheba Rd, 52621, Ramat Gan, Israel.
Tel Aviv University · ILSheba Medical Center · IL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeAbnormal fetal brain measurements might affect clinical management and parental counseling. The effect of between-field-strength differences was not evaluated in quantitative fetal brain imaging until now. Our study aimed to compare fetal brain biometry measurements in 3.0 T with 1.5 T scanners.

methodsA retrospective cohort of 1150 low-risk fetuses scanned between 2012 and 2021, with apparently normal brain anatomy, were retrospectively evaluated for biometric measurements. The cohort included 1.5 T (442 fetuses) and 3.0 T scans (708 fetuses) of populations with comparable characteristics in the same tertiary medical center. Manually measured biometry included bi-parietal, fronto-occipital and trans-cerebellar diameters, length of the corpus-callosum, vermis height, and width. Measurements were then converted to centiles based on previously reported biometric reference charts. The 1.5 T centiles were compared with the 3.0 T centiles.

resultsNo significant differences between centiles of bi-parietal diameter, trans-cerebellar diameter, or length of the corpus callosum between 1.5 T and 3.0 T scanners were found. Small absolute differences were found in the vermis height, with higher centiles in the 3.0 T, compared to the 1.5 T scanner (54.6th-centile, vs. 39.0th-centile, p < 0.001); less significant differences were found in vermis width centiles (46.9th-centile vs. 37.5th-centile, p = 0.03). Fronto-occipital diameter was higher in 1.5 T than in the 3.0 T scanner (66.0th-centile vs. 61.8th-centile, p = 0.02).

conclusionsThe increasing use of 3.0 T MRI for fetal imaging poses a potential bias when using 1.5 T-based charts. We elucidate those biometric measurements are comparable, with relatively small between-field-strength differences, when using manual biometric measurements. Small inter-magnet differences can be related to higher spatial resolution with 3 T scanners and may be substantial when evaluating small brain structures, such as the vermis.

Indexed as

Magnetic Resonance ImagingMagnetsBiometryBrainCohort StudiesFemaleHumansRetrospective StudiesBrainFetal developmentGrowth chartsMagnetic resonance imaging

Identifiers

PMID37436475
OpenAlexW4383998612

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.