Evidence map›Paper›PMID 37436473›Full record

ArticleChild's nervous system : ChNS : official journal of the International Society for Pediatric Neurosurgery2024

Robotic alignment system Cirq (Brainlab) for navigated brain tumor biopsies in children.

Kirsten M van Baarsen, Darwin E A Woodley, K Mariam Slot, Peter A Woerdeman, Kuo S Han, Eelco W Hoving

Abstract read
PubMed Publisher
In one paragraph

Article in Child's nervous system : ChNS : official journal of the International Society for Pediatric Neurosurgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Kirsten M van BaarsenDepartment of Neuro-Oncology, Princess Máxima Center for Pediatric Oncology, Heidelberglaan 25, 3584 CS, Utrecht, The Netherlands. k.m.vanbaarsen-4@prinsesmaximacentrum.nl.
Darwin E A WoodleyDepartment of Neuro-Oncology, Princess Máxima Center for Pediatric Oncology, Heidelberglaan 25, 3584 CS, Utrecht, The Netherlands.
K Mariam SlotDepartment of Neurosurgery, Amsterdam University Medical Centers, Amsterdam, The Netherlands.
Peter A WoerdemanDepartment of Neuro-Oncology, Princess Máxima Center for Pediatric Oncology, Heidelberglaan 25, 3584 CS, Utrecht, The Netherlands.
Kuo S HanDepartment of Neuro-Oncology, Princess Máxima Center for Pediatric Oncology, Heidelberglaan 25, 3584 CS, Utrecht, The Netherlands.
Eelco W HovingDepartment of Neuro-Oncology, Princess Máxima Center for Pediatric Oncology, Heidelberglaan 25, 3584 CS, Utrecht, The Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThe Cirq robotic alignment system (Brainlab, Munich, Germany) is a manually adjustable electronic arm with a robotic alignment module on its distal end, enabling the neurosurgeon to automatically and accurately align surgical instruments to a preoperatively planned trajectory. In this study, we share our first experiences and results using Cirq for intracranial tumor biopsy in children.

methodsFrom May 2021 until October 2022, all consecutive patients that underwent a brain tumor biopsy using Cirq were included and compared to a historical cohort of patients biopsied with the non-robotic system Varioguide (Brainlab, Munich, Germany). Patient-related data, tumor-related data, and surgery-related data were collected. Registration accuracy was calculated for different patient-to-image registration methods. Pre- and postoperative images were fused, and entry error, target error, and angulation error were calculated.

resultsThirty-seven patients, aged 1-19 years, were included (14 with Cirq and 23 with Varioguide). An integrated histopathological and molecular diagnosis was acquired in all cases. Patient-to-image registration was significantly more accurate when based on bone screw fiducials combined with intraoperative CT, as compared to surface matching or skin fiducials. The target error (Euclidian distance) was 5.3 mm for Cirq as compared to 8.3 mm for Varioguide, but this was not statistically significant. Entry error and angulation error were also not significantly different between both groups.

conclusionIntracranial biopsy with the Cirq robotic system is feasible and safe, and its accuracy does not differ from the Varioguide system.

Indexed as

Brain NeoplasmsRobotic Surgical ProceduresBiopsyBone ScrewsChildGermanyHumansBiopsyBrain tumorCirq robotic armNavigationPediatricRobotics

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.