Evidence map›Paper›PMID 37430807›Full record

ArticleSensors (Basel, Switzerland)2023

Wide Temperature Range and Low Temperature Drift Eddy Current Displacement Sensor Using Digital Correlation Demodulation.

Tianxiang Ma, Yuting Han, Yongsen Xu, Pengzhang Dai, Honghai Shen, Yunqing Liu

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Tianxiang MaInformation and Communication Engineering, School of Electronic and Information Engineering, Changchun University of Science and Technology, Changchun 130022, China.
Yuting HanKey Laboratory of Airborne Optical Imaging and Measurement, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.
Yongsen XuKey Laboratory of Airborne Optical Imaging and Measurement, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.
Pengzhang DaiKey Laboratory of Airborne Optical Imaging and Measurement, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.ORCID 0000-0001-8145-9689
Honghai ShenKey Laboratory of Airborne Optical Imaging and Measurement, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.ORCID 0000-0002-8085-9805
Yunqing LiuInformation and Communication Engineering, School of Electronic and Information Engineering, Changchun University of Science and Technology, Changchun 130022, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Conventional eddy-current sensors have the advantages of being contactless and having high bandwidth and high sensitivity. They are widely used in micro-displacement measurement, micro-angle measurement, and rotational speed measurement. However, they are based on the principle of impedance measurement, so the influence of temperature drift on sensor accuracy is difficult to overcome. A differential digital demodulation eddy current sensor system was designed to reduce the influence of temperature drift on the output accuracy of the eddy current sensor. The differential sensor probe was used to eliminate common-mode interference caused by temperature, and the differential analog carrier signal was digitized by a high-speed ADC. In the FPGA, the amplitude information is resolved using the double correlation demodulation method. The main sources of system errors were determined, and a test device was designed using a laser autocollimator. Tests were conducted to measure various aspects of sensor performance. Testing showed the following metrics for the differential digital demodulation eddy current sensor: nonlinearity 0.68% in the range of ±2.5 mm, resolution 760 nm, maximum bandwidth 25 kHz, and significant suppression in the temperature drift compared to analog demodulation methods. The tests show that the sensor has high precision, low temperature drift and great flexibility, and it can instead of conventional sensors in applications with large temperature variability.

Indexed as

digital demodulationdouble correlation demodulationeddy current sensortemperature drift

Identifiers

PMID37430807
PMCPMC10223387

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.