Evidence map›Paper›PMID 37430733›Full record

ArticleSensors (Basel, Switzerland)2023

The Validity of Hawkin Dynamics Wireless Dual Force Plates for Measuring Countermovement Jump and Drop Jump Variables.

Andrew J Badby, Peter D Mundy, Paul Comfort, Jason P Lake, John J McMahon

2 registry-linked trialsOpen access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 48 papers.

0numbers the graph read from it
0cells of the map it votes in
48citing papers in PubMed
18.3field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT06294080 naunknown statusnot on this mapstarted 2024, after this paper: background citation

The Effects of Eight-week Dance and Tai Chi on Balance, Well-being and Mood Among Healthy Adults

TypeinterventionalSponsorUniversity of WolverhamptonRan2024 to 2025Enrolled70ConditionsGeneral PopulationArmsDance, Tai Chi
NCT06900309 nacompletednot on this mapstarted 2025, after this paper: background citation

Effectiveness of a Home-based Telehealth Exercise Program Using the Physitrack App on Adherence and Performance in Handball Players: A Randomized Controlled Pilot Study

TypeinterventionalSponsorCEU San Pablo UniversityRan2025 to 2025Enrolled28ConditionsHealthyArmsSpecific exercise program, General exercise program
3 · Its place in the literature

Who cites it

48 citing papers in PubMed, 79 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Free-fall normalised peak braking velocity for countermovement jump monitoring.BMC sports science, medicine & rehabilitation · 2026
    Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Neuromuscular Profile of CrossFitJournal of functional morphology and kinesiology · 2026
    Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 2 countries.

Andrew J BadbyCentre for Human Movement and Rehabilitation, University of Salford, Salford M6 6PU, UK.
Peter D MundyHawkin Dynamics, Inc., Westbrook, ME 04092, USA.
Paul ComfortCentre for Human Movement and Rehabilitation, University of Salford, Salford M6 6PU, UK.ORCID 0000-0002-1131-8626
Jason P LakeHawkin Dynamics, Inc., Westbrook, ME 04092, USA.ORCID 0000-0003-4381-0938
John J McMahonCentre for Human Movement and Rehabilitation, University of Salford, Salford M6 6PU, UK.ORCID 0000-0001-9952-7846
University of Salford · GBEdith Cowan University · AUUniversity of Chichester · GB

Funding

Hawkin Dynamics Inc. and University of Salford (funded PhD) N/A
6 · The paper itself

Abstract

Force plate testing is becoming more commonplace in sport due to the advent of commercially available, portable, and affordable force plate systems (i.e., hardware and software). Following the validation of the Hawkin Dynamics Inc. (HD) proprietary software in recent literature, the aim of this study was to determine the concurrent validity of the HD wireless dual force plate hardware for assessing vertical jumps. During a single testing session, the HD force plates were placed directly atop two adjacent Advanced Mechanical Technology Inc. in-ground force plates (the "gold standard") to simultaneously collect vertical ground reaction forces produced by 20 participants (27 ± 6 years, 85 ± 14 kg, 176.5 ± 9.23 cm) during the countermovement jump (CMJ) and drop jump (DJ) tests (1000 Hz). Agreement between force plate systems was determined via ordinary least products regression using bootstrapped 95% confidence intervals. No bias was present between the two force plate systems for any of the CMJ and DJ variables, except DJ peak braking force (proportional bias) and DJ peak braking power (fixed and proportional bias). The HD system may be considered a valid alternative to the industry gold standard for assessing vertical jumps because fixed or proportional bias was identified for none of the CMJ variables (n = 17) and only 2 out of 18 DJ variables.

Indexed as

accuracyagreementconcurrent validityforce–timehardwarevertical jumpwireless dual force plate system

Identifiers

PMID37430733
PMCPMC10224001
OpenAlexW4377042545

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.