Evidence map›Paper›PMID 37430692›Full record

ArticleSensors (Basel, Switzerland)2023

Research on a Precision Calibration Model of a Flexible Strain Sensor Based on a Variable Section Cantilever Beam.

Qi Wang, Jianjun Cui, Yanhong Tang, Liang Pang, Kai Chen, Baowu Zhang

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Qi WangSchool of Information Science and Engineering, Zhejiang Sci-Tech University, Hangzhou 310018, China.
Jianjun CuiNational Institute of Metrology, Beijing 100029, China.
Yanhong TangMetrology and Testing Institute of Tibet Autonomous Region, Lhasa 850000, China.
Liang PangMetrology and Testing Institute of Tibet Autonomous Region, Lhasa 850000, China.
Kai ChenNational Institute of Metrology, Beijing 100029, China.
Baowu ZhangCollege of Metrology and Measurement Engineering, China Jiliang University, Hangzhou 310018, China.

Funding

Development of a New Measurement Device for External Thread Parameters Based on a Robotic Arm AKYZZ2204Differential Fabry-Perot Laser Interferometry Microdisplacement Metrology and Applications AKYZD2307Fundamental Research Funds for National Institute of Metrology program of China AKYZD1804-1Key Laboratory of the Ministry of Education for Optoelectronic Measurement Technology and Instrument GXKF2020001National Key Research and Development Program of China 2017YFF0206305Science and Technology Program of Tibet Autonomous Region, Optical Fibre Sensing Characteristics of Low Pressure and High Radiation Environment Application Test Theory and Test Equipment XZ202301YD0004C
6 · The paper itself

Abstract

The flexible strain sensor's measuring range is usually over 5000 με, while the conventional variable section cantilever calibration model has a measuring range within 1000 με. In order to satisfy the calibration requirements of flexible strain sensors, a new measurement model was proposed to solve the inaccurate calculation problem of the theoretical strain value when the linear model of a variable section cantilever beam was applied to a large range. The nonlinear relationship between deflection and strain was established. The finite element analysis of a variable section cantilever beam with ANSYS shows that the linear model's relative deviation is as high as 6% at 5000 με, while the relative deviation of the nonlinear model is only 0.2%. The relative expansion uncertainty of the flexible resistance strain sensor is 0.365% (k = 2). Simulation and experimental results show that this method solves the imprecision of the theoretical model effectively and realizes the accurate calibration of a large range of strain sensors. The research results enrich the measurement models and calibration models for flexible strain sensors and contribute to the development of strain metering.

Indexed as

calibration modelflexible sensorlarge deflectionstrainvariable section cantilever beam

Identifiers

PMID37430692
PMCPMC10222466

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.