Evidence map›Paper›PMID 37430569›Full record

ArticleSensors (Basel, Switzerland)2023

Development and Earliest Validation of a Portable Device for Quantification of Hallux Extension Strength (QuHalEx).

Elizabeth S Hile, Mustafa Ghazi, Raghuveer Chandrashekhar, Josiah Rippetoe, Ashley Fox, Hongwu Wang

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Review
  2. Article
  3. Effect of toe box size on basketball-specific movement performance.Frontiers in bioengineering and biotechnology · 2025
    Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Elizabeth S HileDepartment of Rehabilitation Sciences, University of Oklahoma Health Sciences Center College of Allied Health, 1200 North Stonewall Ave., Oklahoma City, OK 73117, USA.
Mustafa GhaziInfant Neuromotor Control Laboratory, Division of Developmental-Behavioral Pediatrics, Children's Hospital Los Angeles, Los Angeles, CA 90027, USA.
Raghuveer ChandrashekharDepartment of Occupational Therapy, University of Florida, Gainesville, FL 32603, USA.
Josiah RippetoeDepartment of Rehabilitation Sciences, University of Oklahoma Health Sciences Center College of Allied Health, 1200 North Stonewall Ave., Oklahoma City, OK 73117, USA.
Ashley FoxDepartment of Rehabilitation Sciences, University of Oklahoma Health Sciences Center College of Allied Health, 1200 North Stonewall Ave., Oklahoma City, OK 73117, USA.
Hongwu WangDepartment of Occupational Therapy, University of Florida, Gainesville, FL 32603, USA.ORCID 0000-0002-6567-9144

Funding

Tissue Pathology Shared ResourceP30CA225520 · NCI · UNIVERSITY OF OKLAHOMA HLTH SCIENCES CTR · PI ROBERT S. MANNEL · 2018 to 2026
$27.1M
NCI NIH HHS Cancer Center Support Grant P30CA225520 awarded to the University of Oklahoma Stephenson Cancer CenterNCI NIH HHS P30 CA225520
6 · The paper itself

Abstract

Hallux strength is associated with sports performance and balance across the lifespan, and independently predicts falls in older adults. In rehabilitation, Medical Research Council (MRC) Manual Muscle Testing (MMT) is the clinical standard for hallux strength assessment, but subtle weakness and longitudinal changes in strength may go undetected. To address the need for research-grade yet clinically feasible options, we designed a new load cell device and testing protocol to Quantify Hallux Extension strength (QuHalEx). We aim to describe the device, protocol and initial validation. In benchtop testing, we used eight precision weights to apply known loads from 9.81 to 78.5 N. In healthy adults, we performed three maximal isometric tests for hallux extension and flexion on the right and left sides. We calculated the Intraclass Correlation Coefficient (ICC) with 95% confidence interval and descriptively compared our isometric force-time output to published parameters. QuHalEx benchtop absolute error ranged from 0.02 to 0.41 (mean 0.14) N. Benchtop and human intrasession output was repeatable (ICC 0.90-1.00,

Indexed as

Athletic PerformanceHalluxAdultAgedFemaleHumansLongevityLower ExtremityMaleToesYoung Adulthalluxload cellmuscle strengthperformance testing

Identifiers

PMID37430569
PMCPMC10223981

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.